Amcor, Inc.

Struck by running powered equipment during maintenance, cleaning, testing · Avulsions, enucleations without bone loss

Federal OSHA recorded a severe workplace injury at Amcor, Inc., 192 Quality Dr., THOMSON, GEORGIA 30824 on — Avulsions, enucleations without bone loss, affecting the Finger or thumb tip(s), nail(s).

An employee was clearing debris from a bag machine when the clamp closed on his right ring finger and the perforated blade amputated the fingertip without bone loss.

Amputation Finger or thumb tip(s), nail(s) Packaging, bottling, wrapping machinery unspecified

Amcor, Inc.

An employee suffered an injury when his feet and body were pulled through the rollers of the unfolder machine. The employee's feet were tangled on plastic that was on the floor. When the employee reversed the machine, his feet were pulled into it.

View Amcor, Inc.'s full OSHA safety record →

Envelope Seal Insulation, Inc

An employee was inspecting a generator whose radiator was leaking. He slipped, and a fan blade in the generator amputated his thumb and index finger.

CFL USA, LLC

A temporary employee turned off a planer machine, opened the housing, and began clearing a jam. The machine's spinning blade caught his right hand and degloved the index finger.

Bull Moose Tube

An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.

US Battery Manufacturing Company, Inc

A casting machine jammed. An employee's hand was caught in the machine, where a belt line caught and amputated the tip of his finger.

Sargento Foods Inc

A production sanitation employee was pre-rinsing an incline conveyor and noticed cheese stuck between the belt idler. The employee went to remove the cheese and their glove got caught and pulled their left forearm into the conveyor. The employee's arm was fractured. The machine was not locked out/tagged out at the time.

Inteplast Group

An employee was removing plastic material from a production line when the machine cycled and amputated his left index, ring, and little fingers.

Primex Plastics Corporation

An employee was using straps to secure a load inside a transport trailer. The employee was standing on a stack of finished goods that was three pallets high. Each pallet was 16 inches high. He was walking from the stack of three pallets onto a stack of two pallets when he lost his balance and fell onto another stack of finished goods (that was two pallets high) and then landed on the floor of the trailer. The employee was hospitalized with fractured ribs.

Sealed Air

An employee was unclogging a resin sifting machine. The rotary sifter's automatic system activated and the sifter blade struck the employee's fingertip, causing an avulsion. The fingertip was medically amputated.

Sigma Extruding Corp.

An employee was helping to remove a roll of plastic from a line when the tail stock on the machine snapped back and caught the employee's right middle fingertip, resulting in a partial amputation.

MULTIVAC

An employee was investigating a possible issue with a piece of equipment when the equipment started and amputated his left index fingertip.

GS II Building Products, Inc.

An employee was helping to lift the grating from a floor draining system when the grating slipped and landed on his hand, resulting in the amputation of his right middle finger at the first joint.

US Battery Manufacturing Company, Inc

A casting machine jammed. An employee's hand was caught in the machine, where a belt line caught and amputated the tip of his finger.

Alfa Insurance

During a workshop meeting in a hotel, an employee heard a drilling noise, so he walked outside to see what it was. An explosion occurred (possible gas line) and his face, ear, and hair were burned. He also fell and sustained a pelvic fracture.

EMORY UNIVERSITY HOSPITAL

An employee slipped on condensation on a walkway in a parking garage. She fell and suffered a closed fracture to the neck of the left femur.

Bull Moose Tube

An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.