Contact with non-running objects or equipment unspecified · Amputations involving bone loss
At a glance
Federal OSHA recorded a severe workplace injury
at Foundation Steel, LLC, 2450 Sandridge Drive, MORAINE, OHIO 45439
on — Amputations involving bone loss, affecting the Other finger(s) n.e.c..
Final narrative
On May 16, 2025, an employee was performing iron work. He was sliding a 3/4" x 2' x 4' bent plate across another plate to position it for installation. The bent plate crushed his left middle finger between the two steel plates. The distal bone was fractured and required a revision amputation.
Amputation Other finger(s) n.e.c. Panels, sheets, plates metal
An employee fell from a step ladder while reaching for a tie-off point. He impacted the ground, and landed on his bolt bag which contained tools. The employee was hospitalized with fractured ribs, and a lacerated spleen and kidney.
An employee was repairing the suspension of a semi-trailer. He was installing an air bag to the suspension when his left ring finger was crushed between the air bag and the suspension mounting beam. The employee was hospitalized.
An employee was dislodging a towbar and hitch between two golf carts. The upper part of the employee's left index finger was pinched in the towbar/hitch, causing an amputation at the last joint.
An employee was loading a motor onto a trailer when he struck his left elbow against the radiator. His elbow was lacerated and became infected, resulting in hospitalization.
An employee was helping a crew move a section of a grain conveyor that weighed 600-lbs into the proper configuration. The piece of equipment was sitting on a transport cart. While turning the cart to align it, the piece of equipment shifted and the employee's right middle finger was pinched in a small gap between the equipment and the cart. The employee pulled his gloved hand away and suffered a fingertip amputation.
An employee was helping a customer remove a lawn mower from the back of a vehicle. The employee suffered an amputation to their middle fingertip, caused by the lawn mower blades.
More severe injuries in this industry (NAICS 238120)
An employee fell from a step ladder while reaching for a tie-off point. He impacted the ground, and landed on his bolt bag which contained tools. The employee was hospitalized with fractured ribs, and a lacerated spleen and kidney.
An employee was attempting to lift a steel beam from a horizontal, stacked position to a vertical position using a crane. They had placed two hooks on the east side of the beam on the flange. As the employee was hoisting the crane, the beam began to shift and pulled the employee forward onto the stack. When the material shifted, the hooks released and the material fell, pinning the employee between the two beams. The employee was hospitalized with soft tissue contusions on their proximal right thigh and interior left thigh.
An employee was standing on the surface of a steel beam about two feet wide. He slipped and fell backward, landing on the concrete ground about 20 feet below. The employee sustained a broken pelvis.
An employee was unloading a rebar delivery from a flatbed, 19-wheel trailer. The employee rigged the load with wire rope chokers. The load was picked up 3-4 feet above the trailer deck by a crane. The load began to swing and the employee grabbed onto it to prevent it from being pushed off the trailer deck. The crane continued to lift the load, and the employee let go so the crane did not lift him to the third story. The employee fell approximately 12 feet to the ground below, resulting in a back injury and fractured vertebrae.
An employee was attaching a steel angle plate weighing (approximately 200 pounds) to the end of a structural member (5,000 pounds) and was supported by dunnage. The dunnage was a crane mat (11 inches tall) with a 4x6 board on top of it and it supported five identical members. The main piece was 30.75 feet long, 37.25 feet tall, and 1 food wide. As the employee slid the piece of metal on top of the member to begin attaching it, the entire member began to tip over. The employee went to stop the main piece from tipping over and it landed on his ankle, fracturing it.
An employee was working to deliver mail to an apartment building. She was waiting for a customer to move, to obtain clearance to the mailboxes. The door swung inward and closed on her right little finger. The top half of her finger was surgically amputated.
An employee fell from a step ladder while reaching for a tie-off point. He impacted the ground, and landed on his bolt bag which contained tools. The employee was hospitalized with fractured ribs, and a lacerated spleen and kidney.
On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.
An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.
An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.