105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Arcco Power Systems

Exposure through intact tissue · Chemical burns, corrosions degree unspecified

Federal OSHA recorded a severe workplace injury at Arcco Power Systems, 960 1st Street, GRETNA, LOUISIANA 70053 on — Chemical burns, corrosions degree unspecified, affecting the Multiple body parts n.e.c..

An employee was tightening a cooling hose clamp when it failed. Cooling chemicals sprayed onto his arms, stomach, and inner thighs, causing burns.

Hospitalized Multiple body parts n.e.c. Chemicals and hazardous materials unspecified

Sharp International Services, LLC

An employee was removing a hose from a chemical tank after filling the tank with hexamethylenediamine (HMD). He checked the line to ensure that the hose was clear, then disconnected the hose at the connection. Residual chemical sprayed onto his face, causing a second-degree burn. He was hospitalized.

PCI Nitrogen, LLC

A shipping/receiving operator was working on a loading rack, loading a railcar. A 2-inch discharge cap failed and released pressure along with sulfuric acid from the railcar. The acid sprayed onto the employee, who suffered burns to the chest and the lower facial area. The employee was hospitalized.

American Equipment Systems, LLC

An employee was pressure washing truck scales when they were splashed with water and an unknown chemical on their leg and immediately experienced a burning sensation. The employee was hospitalized with a chemical burn and required surgery.

Innovative Chemical Technologies

An employee was on a ladder disconnecting a 1-inch hose, known to have last carried acrylic acid that had been drained. When the hose was disconnected, residual acid dripped onto the employee's shoulder/arm area, causing a second-degree chemical burn.

Pen Gulf, Inc.

Employees were removing scaffolding that was used to repair an ion exchange tank. The line was undergoing the regen process when a piece of scaffold struck a PVC pipe that transported hydrochloric acid (HCl). The injured employee was placing material inside a scaffold rack when he was sprayed in the face with HCl and sustained chemical burns to his eyes, face, chest, right arm, and left leg.

American Electric Power Company

An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.

Cherokee Electric Cooperative

An employee (a lineman) was working to restore power by installing a hand line when he contacted a high-voltage device (7,200 volts), resulting in electrical burns to his upper body and hands.

Centerpoint Energy Houston Electric, LLC

A chain sling failed while a utility pole was being removed. A chain link struck an employee who was operating a front-end loader, puncturing the employee's chest.

Public Service Electric & Gas

An employee was working with an underground crew to troubleshoot a BUD failure. The employee was removing a fuse from the fuse holder when the fuse blew on the riser and an arc flash occurred. The employee was hospitalized with burns to his face, nose, lips, and neck.

Bright Star Solutions, Inc

An employee was connecting two wires when his rubber insulated gloves failed and he suffered an electric shock to his right hand, resulting in an electrical burn.

Kisatchie Midnight Express

A driver was exiting his vehicle outside the plant gate when his foot slipped on the top step of the truck. He fell to the ground, landed on his left hip and elbow. The employee was hospitalized with a fractured hip/femur.

CHRISTUS St. Frances Cabrini Hospital

A security employee was responding to an urgent call from staff regarding a violent patient. The employee tripped and fell on the floor outside of the stairwell. The employee sustained a closed head injury, contusion of the cerebrum without loss of consciousness, and a closed fracture of the distal end of the right radius.

Jean Simpson Personnel Services, Inc.

A temporary employee was testing an electrical starter motor. He was placing tape on the starter while the breaker was not engaged, but the starter sent an arc flash that burned his hands and stomach.

Calvary Industries Inc

An employee was walking on a sidewalk and stubbed his toe on an elevated portion of concrete, causing him to trip and fall. The employee's right knee was dislocated.