Struck by running powered equipment during maintenance, cleaning, testing · Amputations, avulsions, enucleations unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at Delphos Rubber Company, 1430 N. Main Street, DELPHOS, OHIO 45833
on — Amputations, avulsions, enucleations unspecified, affecting the Finger or thumb tip(s), nail(s).
Final narrative
A temporary employee was working to remove a detached piece of rubber EPDM product that was hanging on the outside of a feed chute. As the employee grabbed the elongated material, the material reengaged inside the machine above the feed chute and pulled back, pinching their left index fingertip. The employee's fingertip was amputated.
A temporary employee turned off a planer machine, opened the housing, and began clearing a jam. The machine's spinning blade caught his right hand and degloved the index finger.
An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.
A production sanitation employee was pre-rinsing an incline conveyor and noticed cheese stuck between the belt idler. The employee went to remove the cheese and their glove got caught and pulled their left forearm into the conveyor. The employee's arm was fractured. The machine was not locked out/tagged out at the time.
More severe injuries in this industry (NAICS 326299)
An employee was guiding a conveyor belt through a slitter when their hand was caught between the rollers and the table. When the employee pulled their hand out, the glove was left behind and their right middle fingertip was amputated.
A maintenance employee was working to place a 120-pound metal screen on top of a machine before installation, with the help of another employee. The injured employee's right ring finger was pinched between the screen and the machine and the fingertip was partially amputated.
On September 26, 2025, an employee was performing maintenance on an excavator when a bale of rubber fell from an adjacent rack and struck him. The employee sustained multiple fractures to his pelvic area.
An employee was cleaning a mixer door. The employee's left hand came into contact with the mixer blade, which was still slowly rotating. The employee suffered amputations to the left index and middle fingertips.
An employee was using a mechanical grinder when his right middle and ring fingers came into contact with its blades. Both fingers were partially amputated.
An employee was working to deliver mail to an apartment building. She was waiting for a customer to move, to obtain clearance to the mailboxes. The door swung inward and closed on her right little finger. The top half of her finger was surgically amputated.
An employee fell from a step ladder while reaching for a tie-off point. He impacted the ground, and landed on his bolt bag which contained tools. The employee was hospitalized with fractured ribs, and a lacerated spleen and kidney.
On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.
An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.
An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.