Compressed between running equipment and other object(s) · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at Ayad Electric LLC, 6736 Carlisle Pike, MECHANICSBURG, PENNSYLVANIA 17050
on — Fractures , affecting the Exterior and musculoskeletal structures of the neck.
Final narrative
An employee was operating a scissor lift inside the machine room. He went to drive the lift forward, but the lift elevated instead, pinning him between the platform and a ceiling joist. The employee lost consciousness and required CPR. The employee was hospitalized with a fractured neck.
Hospitalized Exterior and musculoskeletal structures of the neck Hoists, lifts scissor, telescoping
An employee was working to build an electrical substation. He was cleaning out the inside of a fixed section of a PVC pipe on the end that was furthest from an excavator. The excavator was outside of the trench and more than 25 feet away when it moved a pipe, pinching the employee's right arm between the two pipes. The employee's forearm was fractured.
An employee was anchored to a movable piece of equipment called a "lid" with a self-retracting lifeline harness. An overhead crane lifted the equipment, causing the employee to be pulled by his harness. The employee was pulled off the walkway and swung over the wall of the kiln. His body and head struck the wall. The employee lost consciousness and sustained a laceration to the side of his head that required stitches. The employee also sustained multiple fractured ribs and fractured vertebrae.
An employee was in a scissor lift, preparing to strip formwork from the underside of a concrete deck. As the lift was ascending, the employee's left little finger was pinched between the lift rail and the concrete beam above. The employee was hospitalized, and the soft tissue of their left little fingertip was amputated; the finger's bony tuft was also damaged.
An employee was operating an order picker when his left middle finger was crushed between the lift and storage racking. The employee's fingertip was amputated.
An employee was ascending in a scissor lift when his left thumb was caught between between the railing of the lift and a piece of equipment installed in the ceiling. The employee's thumb tip was amputated.
More severe injuries in this industry (NAICS 238210)
An employee was troubleshooting the control setup for a variable air volume box above a ceiling. The employee's hand came into contact with an exposed, energized 277-volt wire that had loosened from its terminal on the box's assembly. He was shocked and fell off a ladder. His left hand passed across the ceiling grid and was lacerated. He also suffered an electrical burn to the right hand and was hospitalized.
An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.
An employee was standing on an A-frame ladder approximately 6 feet above the floor while he attached a suspended light fixture to the ceiling. The employee lost balance, and fell to the tiled floor below, sustaining blunt force trauma to his head.
An employee was inspecting the overhead area of a single-person lift and repositioning the lift through a double doorway. As they were transitioning through the doorway, they were caught between the doorframe and the vertical mast of the lift. The employee was hospitalized with injuries to the nose, left maxillary sinus, left orbital bone, and left jaw, with fractures at the maxillary sinus area.
The injured employee was performing routine maintenance on a fan belt/pulley. The injured employee and another person were moving the pulley back and forth manually to find a bearing issue. The injured employee's left ring finger got caught between the belt and the pulley wheel, resulting in a soft tissue amputation.
An employee was walking into the motor control center (MCC) room when his right ring finger was caught in the hinge of a doorway. He sustained an open phalanx fracture, which resulted in a partial amputation above the first knuckle.
An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.
An employee was pulling down a broken skid with a forklift. When the employee backed up the forklift to get the forks out of the skid he pulled down, he contacted the forks of another parked forklift, fracturing both of his legs. He was hospitalized.
An employee was carrying cups back to the kitchen when her foot got caught on a cart and she fell face-first. During the fall, a piece of glass from a cup cut the inside of her mouth, severing an artery. She also sustained a laceration on her lower lip. The employee was hospitalized.