Federal OSHA recorded a severe workplace injury
at HEXPOL Compounding PC, Inc., 155 Stoffel Drive, TALLAPOOSA, GEORGIA 30176
on — Fractures , affecting the Knee(s).
Final narrative
Two employees were lifting a roll of steel poly bar (50 inches and approximately 150 pounds) from ground level to a height of 4 feet at the 66-inch rubber calendar. One employee dropped the roll, resulting in the poly bar contacting the injured employee's right knee. The employee was hospitalized with fractured right patella.
An employee was helping to lift the grating from a floor draining system when the grating slipped and landed on his hand, resulting in the amputation of his right middle finger at the first joint.
An employee and co-worker were working to unjam and move a 100-pound piece of crossed-up cant timber. The employee lost their grip and the timber fell on their right hand, resulting in crush injuries to the fingers.
An employee was working on a cushion ring (steel). As they lifted the cushion ring with both hands to flip it up, the ring slid down and the employee's right middle fingertip was crushed between the ring and the work table. The employee was hospitalized with a fracture, and their right middle fingertip was amputated.
The injured employee was walking in front of the property by the front door as another employee was removing debris from the roof. The injured employee was struck by a 2 x 4 that was being cleared from the roof. He was knocked unconscious and sustained brain bleeding, as well as head and facial injuries, and required stitches.
Employees were loading a 295-pound transformer onto a pickup truck using a forklift. The injured employee was acting as the spotter. The transformer hit the tailgate of the pickup truck and the spotter's right hand was struck by the transformer, resulting in amputation of the ring fingertip.
An employee was wearing full PPE while emptying a 55-gallon drum of phosphorus pentoxide and fainted, collapsing and striking their head against the ground. The employee was hospitalized and it is likely that heat caused by wearing full body PPE contributed to fainting.
An employee was troubleshooting a plug in the super-absorbent polymer line. The employee opened an inspection port and their right hand was caught in a rotary valve, resulting in the amputation of four fingers between the knuckle and the first joint.
An employee was conducting a quality control measure by taking a chemical sample for lab analysis. When the employee was opening the sample point, it broke off and crude 2-Ethylhexyl thioglycolate (EHTG) shot out at 265 degrees, and it covered the employee's legs and right arm and splashed the right side of their face. The employee was hospitalized with first- and second-degree burns to their right thigh, lower right knee, inner left thigh, and upper left forearm.
An employee was performing a routine tank change when phosgene gas was released. The employee was exposed to the gas for about a minute. After about six hours, the employee developed respiratory distress symptoms. The employee was hospitalized.
An employee was helping to lift the grating from a floor draining system when the grating slipped and landed on his hand, resulting in the amputation of his right middle finger at the first joint.
During a workshop meeting in a hotel, an employee heard a drilling noise, so he walked outside to see what it was. An explosion occurred (possible gas line) and his face, ear, and hair were burned. He also fell and sustained a pelvic fracture.
An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.