Inhalation of harmful substance single episode or single shift · Poison, toxic, or allergenic effects other respiratory
At a glance
Federal OSHA recorded a severe workplace injury
at MCM Plastics, Inc., 30070 Dan Pierson Rd, HOLDEN, LOUISIANA 70744
on — Poison, toxic, or allergenic effects other respiratory, affecting the BODY SYSTEMS .
Final narrative
An employee was sweeping in an area with powdered PVC on the floor and began having difficulty breathing and coughing up blood, The employee was hospitalized for inhalation of PVC.
An employee was working in the food service warehouse when he experienced chest pain, difficulty breathing, and lost consciousness. The employee sustained carbon monoxide poisoning.
An employee was performing janitorial duties on the 15th floor of a building that was under construction. She began having trouble breathing. The employee was hospitalized with lung irritation caused by dust.
An employee opened a flammables storage cabinet to get something out, smelled a chemical odor, and began to feel unwell and dizzy. She was hospitalized, having been exposed to formic acid from a leaking bottle at the bottom of the cabinet.
More severe injuries in this industry (NAICS 325211)
An employee was monitoring a rotary press when his left hand became caught in the machinery. The employee's left middle finger was amputated at the distal interphalangeal joint.
An employee was working on a pastillator machine, which processes resin-based materials into solid pastilles. His right hand became caught between the feed roller (operating at approximately 350 F) and the cooling belt. The employee s glove and shirt sleeve adhered to his arm due to the heat. The employee sustained third-degree burns to his right hand and forearm, requiring hospitalization and surgery.
An employee was troubleshooting a leak on a low pressure (less than 50 PSI) condensate line in the oxidation area of the plant. He was working to remove insulation around a valve when either the valve or the line failed, and hot condensate contacted his right arm, right abdomen area, and the front of both legs, resulting in second- and third-degree burns.
An employee was replacing a fan on a cooling unit. As he went to adjust a pump, the unit caught his right hand and the fan blades severely lacerated his index finger. He underwent a medical amputation to the finger.
An employee was removing plastic that was entangled in a roller when their right forearm was caught in the powered conveyor roller. The employee was hospitalized with a fractured forearm.
A driver was exiting his vehicle outside the plant gate when his foot slipped on the top step of the truck. He fell to the ground, landed on his left hip and elbow. The employee was hospitalized with a fractured hip/femur.
A security employee was responding to an urgent call from staff regarding a violent patient. The employee tripped and fell on the floor outside of the stairwell. The employee sustained a closed head injury, contusion of the cerebrum without loss of consciousness, and a closed fracture of the distal end of the right radius.
A temporary employee was testing an electrical starter motor. He was placing tape on the starter while the breaker was not engaged, but the starter sent an arc flash that burned his hands and stomach.
An employee was walking on a sidewalk and stubbed his toe on an elevated portion of concrete, causing him to trip and fall. The employee's right knee was dislocated.