Other fall to lower level less than 6 feet · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at J. & M. BROWN COMPANY, INC., 20 Carematrix Drive Suite 300, DEDHAM, MASSACHUSETTS 02026
on — Fractures , affecting the Lower leg(s).
Final narrative
An employee was installing a light fixture. While descending a 6-foot ladder, they missed the third rung and fell to the ground. The employee's tibia and fibula were fractured.
Hospitalized Lower leg(s) Portable ladders and stairs unspecified
An employee fell while exiting a trailer. The employee landed on their left side on the pavement, suffering multiple broken ribs on the left side. The employee was hospitalized.
A driver was exiting his vehicle outside the plant gate when his foot slipped on the top step of the truck. He fell to the ground, landed on his left hip and elbow. The employee was hospitalized with a fractured hip/femur.
Two employees were removing a service lift platform from the back of a radar system. While handling the service lift platform, employee 2 was standing on the back of the radar and lost their footing, causing the service lift platform to shift and fall. The injured employee then fell from the top of the platform electronic subsystem (PES) to the floor, approximately 56 inches. The injured employee fractured his left elbow and left hip.
An employee fell from a loading dock to the ground 2-3 feet below. She suffered a compound fracture of the left hip and was hospitalized, requiring surgery.
An employee assisted in cleaning material from a conveyor pit. After the pit was cleaned, the employee proceeded to replace metal safety plates to ensure other employees did not fall into the pit. While replacing one of the last plates, the employee mis-stepped and fell approximately 5 feet into the pit. The employee was hospitalized with back/side bruising, elbow bruising, bone bruises, and/or fractured ribs.
More severe injuries in this industry (NAICS 238210)
An employee was troubleshooting the control setup for a variable air volume box above a ceiling. The employee's hand came into contact with an exposed, energized 277-volt wire that had loosened from its terminal on the box's assembly. He was shocked and fell off a ladder. His left hand passed across the ceiling grid and was lacerated. He also suffered an electrical burn to the right hand and was hospitalized.
An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.
An employee was standing on an A-frame ladder approximately 6 feet above the floor while he attached a suspended light fixture to the ceiling. The employee lost balance, and fell to the tiled floor below, sustaining blunt force trauma to his head.
An employee was inspecting the overhead area of a single-person lift and repositioning the lift through a double doorway. As they were transitioning through the doorway, they were caught between the doorframe and the vertical mast of the lift. The employee was hospitalized with injuries to the nose, left maxillary sinus, left orbital bone, and left jaw, with fractures at the maxillary sinus area.
The injured employee was performing routine maintenance on a fan belt/pulley. The injured employee and another person were moving the pulley back and forth manually to find a bearing issue. The injured employee's left ring finger got caught between the belt and the pulley wheel, resulting in a soft tissue amputation.
An employee fell while exiting a trailer. The employee landed on their left side on the pavement, suffering multiple broken ribs on the left side. The employee was hospitalized.
Two employees were setting up a mandrel in the spindle of a machine. The mandrel was side-shifted while an employee's hand was on the mast of a powered industrial truck. The employee suffered crushing injuries that resulted in amputations to the middle and ring fingertips.
An employee had been loading a double deck press. The employee saw a mold had been sent in with the C-hook still attached on the belly bar. As he went to remove the hook from the mold, his right thumb got caught on the C-hook. The employee's thumb was partially amputated.
An employee was operating a roller and paving a small pathway next to a pavilion. The ground was on a slight pitch, causing him to reach up toward the roll cage to stabilize himself. His right fifth finger was pinched between the roll cage and the rafter of the pavilion. The employee sustained a partial degloving injury with partial traumatic amputation.
An employee was delivering home heating fuel when bees came from the ground and stung the employee's face, neck, torso, and hands. The employee proceeded to shut off the oil flow before losing consciousness. They were hospitalized due to an anaphylactic reaction.