105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Air-flo/Erwood Heating & Air Conditioning

Fall on same level n.e.c. · Sprains, strains, tears unspecified

Federal OSHA recorded a severe workplace injury at Air-flo/Erwood Heating & Air Conditioning, 2075 CAROLINA AVE NE, SAINT PETERSBURG, FLORIDA 33703 on — Sprains, strains, tears unspecified, affecting the Exterior and musculoskeletal structures of the neck.

An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.

Hospitalized Exterior and musculoskeletal structures of the neck Other constructed surface

Gateway Healthcare, Inc.

An employee was talking to a child on the playground, when the child grabbed her hand to lead her away. The employee stepped, lost her balance, and fell over. The employee was hospitalized with a fracture of her lower left leg and required surgery.

XPO

An employee was lowering a safe stack beam inside a trailer. The beam released, causing the employee to fall back and strike his head on the trailer floor. He was hospitalized with a brain bleed and a concussion.

J-Mar Enterprises

An employee was on the ground working to close a trailer door. The door was caught by the wind and blew the employee backward. He landed on his back and sustained four fractured ribs, requiring hospitalization.

Meijer Stores Limited Partnership

An employee was pulling a display shipper using the provided strap. The strap broke and the employee fell to the floor, suffering a broken wrist.

Corrigan Brothers Inc

An employee was closing the side cargo door to a company van. The tip of his finger got caught between the door and the door jamb, resulting in a partial amputation.

Village Plumbing, Air & Electric

While working at a customer's residence, an employee was cutting tape with a box cutter to wrap insulation for a piece of pipe. The box cutter struck a hardened object within the wall causing it to bounce back and puncture the employee's right eye. The employee was hospitalized.

Goodrich Fire & Life Safety

An employee was assembling a baker type scaffold. He was beginning to transverse down the scaffold, approximately six feet off the ground, when the scaffold tipped over and he fell. The employee was hospitalized with a fractured femur.

Sprinklermatic Fire Protection Systems, Inc.

An employee was trimming out sprinklers on the exterior of a building when he fell off an extension ladder. He landed on the ground and sustained fractures to his nose and arm.

Frontier Mechanical, Inc.

An employee was cutting a PVC pipe when the saw slipped, amputating his left ring fingertip. The fingertip was reattached.

DRIFTWOOD NURSERY & LANDSCAPING, INC

An employee was helping a coworker transport a tall palm tree with a mini skid steer. The employee was severely shocked by a high-voltage electrical wire above the ground.

Hobby Lobby Stores, Inc.

An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.

Envelope Seal Insulation, Inc

An employee was inspecting a generator whose radiator was leaking. He slipped, and a fan blade in the generator amputated his thumb and index finger.

Sugar Cane Growers Cooperative of Florida

An employee was operating an agricultural tractor during sugarcane harvesting. The employee sustained a lumbar sprain due to vibration or motion from the tractor.

New Millennium Building Systems

An employee was moving metal out of a cart. He had removed one piece and was working to move another when the metal shifted. His right ring finger was crushed between the two pieces, and he suffered a partial amputation to the finger pad at the tip.