Knoxville, TN —
OSHA Injury Report: Kelvion Prodcuts
Injury · Days away from work
At a glance
On , an injury at Kelvion Prodcuts in 5050 S. National Drive, Knoxville, TN 37914 resulted in days away from work. Employee was welder in heat exchangers manufacturing.
Where did this happen?
- Establishment
- Kelvion Prodcuts
- Parent company
- Kelvion Products, Inc.
- Street
- 5050 S. National Drive
- City
- Knoxville
- State
- TN
- ZIP
- 37914
- On-site location
- KNX3 - PHE
What was the outcome?
- Outcome
- Days away from work (code 2)
- Type
- Injury (code 1)
- Days away from work
- 11
Before the incident
Employee was welding.
What happened
Following heavy rains part of the roof collapsed onto the employee striking him in the face.
Injury or illness
Facial fractures.
Object or substance involved
Roof debris.
Summary line
Employee struck in face by collapsing roof resulting in facial fractures.
Employee and industry
- Job description
- Welder
- SOC code
- 51-4121 — Welders, Cutters, Solderers, and Braze-rs
- NAICS code
- 332410 — Heat exchangers manufacturing
- NAICS vintage
- 2022
- Avg employees
- 284
- Total hours worked
- 648725
- Establishment ID
- 1289312
- Employer case #
- 5
When (timing detail)
- Date of incident
- Shift started
- 4:00
- Time of incident
- 13:00
- Filing year
- 2024
- Submitted
- 04FEB2025:17:35:00
More injuries at Kelvion Prodcuts
Knoxville, TN—
Kelvion Prodcuts
Knoxville, TN—
Kelvion Prodcuts
Knoxville, TN—
Kelvion Prodcuts
Knoxville, TN—
Kelvion Prodcuts
Knoxville, TN—
Kelvion Prodcuts
View Kelvion Prodcuts's full OSHA safety record →
More injuries in this industry (NAICS 332410)
Collinsville, OK—
Victory Energy Operations
TEXAS CITY, TX—
Dunn Heat Exchangers- Texas City
Barberton, OH—
NOG-B
Mesa, AZ—
Super Radiator Coils - Mesa I
Murrieta, CA—
CRYOQUIP LLC
More injuries in TN
ALCOA, TN—
WM 672
MADISONVILLE, TN—
WM 366
CLINTON, TN—
WM 4635
CLARKSVILLE, TN—
First Call Ambulance
BRISTOL, TN—
WM 620
Source
Data from OSHA ITA Form 300/301 electronic submissions, filing year 2024. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.