Anderson, IN —
OSHA Injury Report: Nestle USA
Injury · Other recordable case
At a glance
On , an injury at Nestle USA in 4301 W 73rd St, Anderson, IN 46013 resulted in other recordable case. Employee was apprentice Mechanical in acidophilus milk manufacturing.
Where did this happen?
- Establishment
- Nestle USA
- Parent company
- Nestle USA
- Street
- 4301 W 73rd St
- City
- Anderson
- State
- IN
- ZIP
- 46013
- On-site location
- LP - UHT - Line 6 Expansion Tank
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Injury (code 1)
Before the incident
Removing a level transmitter on the expansion tank.
What happened
When the level transmitter was removed hot water flowed out of the tank.
Injury or illness
Thermal burn to the right forearm
Object or substance involved
Hot Water
Summary line
Second degree burns on right forearm from hot water.
Employee and industry
- Job description
- Apprentice Mechanical
- SOC code
- 9999 — Uncoded
- NAICS code
- 311511 — Acidophilus milk manufacturing
- NAICS vintage
- 2012
- Avg employees
- 738
- Total hours worked
- 1728431
- EIN
- 951572209
- Establishment ID
- 599736
- Employer case #
- 24-01
When (timing detail)
- Date of incident
- Shift started
- 6:00
- Time of incident
- 7:23
- Filing year
- 2024
- Submitted
- 24FEB2025:22:11:00
More injuries at Nestle USA
Anderson, IN—
Nestle USA
Anderson, IN—
Nestle USA
Anderson, IN—
Nestle USA
Anderson, IN—
Nestle USA
Anderson, IN—
Nestle USA
View Nestle USA's full OSHA safety record →
More injuries in this industry (NAICS 311511)
FRESNO, CA—
00060351-60351 SHEHADEY FAMILY FOODS, LLC
ATHENS, TN—
DFA FLUID - ATHENS TN
Asheville, NC—
Milkco
Winter Haven, FL—
Winter Haven Florida Facility
Evans City, PA—
Marburger Farm Dairy, INC
More injuries in IN
AUBURN, IN—
WM 1570
CLARKSVILLE, IN—
WM 1476
INDIANAPOLIS, IN—
WM 1459
Evansville, IN—
Ameriqual Foods
Indianapolis, IN—
Volumod
Source
Data from OSHA ITA Form 300/301 electronic submissions, filing year 2024. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.