Defiance, OH —
OSHA Injury Report: Defiance 8
Injury · Other recordable case
At a glance
On , an injury at Defiance 8 in 925 Carpenter Road, Defiance, OH 43512 resulted in other recordable case. Employee was mAINTENANCE MECHANIC in fiberglass Insulation Products Manufacturing.
Where did this happen?
- Establishment
- Defiance 8
- Parent company
- Johns Manville
- Street
- 925 Carpenter Road
- City
- Defiance
- State
- OH
- ZIP
- 43512
- On-site location
- COLDEND,89
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Injury (code 1)
Before the incident
Removing motor to repair gear box.
What happened
Employee struck by motor motor bracket falling after he removed the bolts.
Injury or illness
Elbow contusion
Object or substance involved
Motor motor bracket
Summary line
Other: Contusion Elbow: Contusion; Equipment: Motor Motor Bracket
Employee and industry
- Job description
- MAINTENANCE MECHANIC
- SOC code
- 49-9071 — Maintenance and Repair Workers, General
- NAICS code
- 327993 — Fiberglass Insulation Products Manufacturing
- NAICS vintage
- 2022
- Avg employees
- 501
- Total hours worked
- 1063534
- EIN
- 130889690
- Establishment ID
- 1512751
- Employer case #
- 41502
When (timing detail)
- Date of incident
- Shift started
- 0:08
- Time of incident
- 13:40
- Filing year
- 2025
- Submitted
- 26FEB26:17:13:00
More injuries at Defiance 8
Defiance, OH—
Defiance 8
Defiance, OH—
Defiance 8
Defiance, OH—
Defiance 8
Defiance, OH—
Defiance 8
Defiance, OH—
Defiance 8
View Defiance 8's full OSHA safety record →
More injuries in this industry (NAICS 327993)
Winder, GA—
Winder
McPherson, KS—
McPherson
Walworth, WI—
USG Interiors Walworth
Kearneysville, WV—
ROCKWOOL RAN5
Cloquet, MN—
USG Interiors Cloquet
More injuries in OH
CANTON, OH—
WM 5285
LEWIS CENTER, OH—
WM 2725
EASTLAKE, OH—
WM 1863
SPRINGFIELD, OH—
02 SPRINGFIELD MASONIC COMMUNITY 02 SPRINGFIELD MASONIC COMMUNITY
Cleveland, OH—
Fairview Hospital
Source
Data from OSHA ITA Form 300/301 electronic submissions, filing year 2025. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.