Gladys, VA —
OSHA Injury Report: VA019 Brookneal OSB
Injury · Other recordable case
At a glance
On , an injury at VA019 Brookneal OSB in 11795 Brookneal Hwy, Gladys, VA 24554 resulted in other recordable case. Employee was maintenance and Trades Electricians Ind Prod Worker.
Where did this happen?
- Establishment
- VA019 Brookneal OSB
- Street
- 11795 Brookneal Hwy
- City
- Gladys
- State
- VA
- ZIP
- 24554
- On-site location
- #1 Cyclone Fire Reversal Belt
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Injury (code 1)
Before the incident
Holding a rope to support the drag belt.
What happened
Left pinky finger caught between supporting rope and fire reversal belt resulting in left hand fracture.
Injury or illness
1
Object or substance involved
Suspended Energy
Summary line
Left Pinky Finger Fractured when caught between conveyor belt and structure
Employee and industry
- Job description
- Maintenance and Trades Electricians Ind Prod Worker
- SOC code
- 47-2111 — Electricians
- NAICS code
- 321219
- NAICS vintage
- 2022
- Avg employees
- 127
- Total hours worked
- 285738
- EIN
- 562306374
- Establishment ID
- 1003552
- Employer case #
- 1113991
When (timing detail)
- Date of incident
- Shift started
- 19:00:00.000
- Time of incident
- 4:00:00.000
- Submitted
- 23FEB24:16:52:00
More injuries at VA019 Brookneal OSB
Gladys, VA—
VA019 Brookneal OSB
Gladys, VA—
VA019 Brookneal OSB
Gladys, VA—
VA019 Brookneal OSB
Gladys, VA—
VA019 Brookneal OSB
Gladys, VA—
VA019 Brookneal OSB
View VA019 Brookneal OSB's full OSHA safety record →
More injuries in this industry (NAICS 321219)
Towanda, PA—
Woodgrain Towanda Pa
Willacoochee, GA—
Langboard MDF
Medford, OR—
Medford Particleboard
Newark, OH—
Tectum
Green Bay, WI—
Louisiana-Pacific Green Bay
More injuries in VA
Gloucester, VA—
Riverside Walter Reed Hospital 5001
DANVILLE, VA—
WM 4996
COVINGTON, VA—
WM 2662
MADISON HEIGHTS, VA—
WM 2565
FREDERICKSBURG, VA—
WM 1833
Source