Bath, PA —
OSHA Injury Report: EFI
Injury · Job transfer or restriction
At a glance
On , an injury at EFI in 6980 Chrisphalt Dr, Bath, PA 18014 resulted in job transfer or restriction. Employee was shipping in steel foundries (except investment).
Where did this happen?
- Establishment
- EFI
- Parent company
- Effort foundry Inc
- Street
- 6980 Chrisphalt Dr
- City
- Bath
- State
- PA
- ZIP
- 18014
- On-site location
- Shipping Dept-Wheelabrator
What was the outcome?
- Outcome
- Job transfer or restriction (code 3)
- Type
- Injury (code 1)
- Days restricted or transferred
- 31
Before the incident
opening wheelabrator door in shipping dept.
What happened
As door opened on wheelabrator test bar fell out jamming door which caused it to abruptly close. This made his right arm jerk.
Injury or illness
strain right shoulder
Object or substance involved
door of wheelabrator
Summary line
While opening Wheelabrator door test bar fell out-jamming door which caused an abrupt shutting of door. right shoulder strain
Employee and industry
- Job description
- Shipping
- SOC code
- 43-5071 — Shipping, Receiving, and Inventory Clerks
- NAICS code
- 331513 — Steel foundries (except investment)
- NAICS vintage
- 2022
- Avg employees
- 82
- Total hours worked
- 177045
- EIN
- 231910857
- Establishment ID
- 93142
- Employer case #
- 202305
When (timing detail)
- Date of incident
- Shift started
- 6:00:00.000
- Time of incident
- 9:00:00.000
- Submitted
- 26FEB24:15:44:00
More injuries at EFI
View EFI's full OSHA safety record →
More injuries in this industry (NAICS 331513)
Pigeon, MI—
Huron Casting Inc
Pigeon, MI—
Huron Casting Inc
Pigeon, MI—
Huron Casting Inc
Pigeon, MI—
Huron Casting Inc
Milwaukee, WI—
Maynard Steel Casting Company
More injuries in PA
Aston, PA—
Thayer Distribution
POTTSVILLE, PA—
WM 7030
CONNELLSVILLE, PA—
WM 5379
ETTERS, PA—
WM 4404
DUNCANSVILLE, PA—
WM 4348
Source
Data from OSHA ITA Form 300/301 electronic submissions, filing year unspecified. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.