Albany, OR —
OSHA Injury Report: NWI Defense
Injury · Other recordable case
At a glance
On , an injury at NWI Defense in 125 34th Ave SW, Albany, OR 97322 resulted in other recordable case. Employee was cNC Machinist in copper forgings made from purchased metals, unfinished.
Where did this happen?
- Establishment
- NWI Defense
- Parent company
- NWI Holdings, LLC
- Street
- 125 34th Ave SW
- City
- Albany
- State
- OR
- ZIP
- 97322
- On-site location
- Production bay
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Injury (code 1)
Before the incident
machining parts in CNC machine
What happened
Missing section of program caused a X axis home position move while the tool was inside of the part. The program was not fully proofed out after edits made on [REDACTED].
Injury or illness
laceration of middle finger of right hand
Object or substance involved
cutting tool
Summary line
laceration of middle finger of right hand
Employee and industry
- Job description
- CNC Machinist
- SOC code
- 51-9161 — Computer Numerically Controlled Tool Operators
- NAICS code
- 332112 — Copper forgings made from purchased metals, unfinished
- NAICS vintage
- 2022
- Avg employees
- 34
- Total hours worked
- 64733
- EIN
- 833006760
- Establishment ID
- 1229804
- Employer case #
- 13
When (timing detail)
- Date of incident
- Shift started
- 5:30:00.000
- Filing year
- 2023
- Submitted
- 05MAR24:20:41:00
More injuries at NWI Defense
Albany, OR—
NWI Defense
Albany, OR—
NWI Defense
Albany, OR—
NWI Defense
Albany, OR—
NWI Defense
Albany, OR—
NWI Defense
View NWI Defense's full OSHA safety record →
More injuries in this industry (NAICS 332112)
Paramount, CA—
Weber Metals Inc.
Stuarts Draft, VA—
09 - Stuarts Draft
Albion, IN—
Fluid Connectors Albion
El Cajon, CA—
Precision Metal Products
Stuarts Draft, VA—
09 - Stuarts Draft
More injuries in OR
TIGARD, OR—
WM 5935
Portland, OR—
Dynalectric Oregon
Redmond, OR—
Renewal - Redmond
TROUTDALE, OR—
80001021-PORT PORTLAND-G972
PORTLAND, OR—
80001021-NPRS NORTH PORTLAND RSF-G938
Source
Data from OSHA ITA Form 300/301 electronic submissions, filing year 2023. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.