Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BRYANT ELECTRIC CO.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of BRYANT ELECTRIC CO. in EAST GADSDEN WASTE WATER PLANT, GADSDEN, AL 35901 (NAICS 000000). OSHA activity number 106234602.

Watch Bryant Electric CO. — free Get an email when a new federal OSHA severe-injury report for Bryant Electric CO. is published. One employer, no account, unsubscribe in one click.
Establishment
BRYANT ELECTRIC CO.
Site address
EAST GADSDEN WASTE WATER PLANT
City
GADSDEN
State
AL
ZIP
35901
Mailing
P. O. BOX 8081, GADSDEN, AL 35901
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1622
Employees
9
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 08 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $640.00 · Current $330.00 Reduced
Section 5(a)(1) of the Occpational Safety and Health Act of 1970:  The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
a) Gadsden sewer rehabilitation, Riverside Drive, along reverfront
employees come in contract with raw sewage which may contain blood
and other body fluids, thereby exposing employees to the hazard of
being infected by HBV.
Among other methods, one feasible and acceptable means of correct this
hazard include:
1) Offer employees hepatitis B vaccinations free of charge in amounts
and at times prescribed by standard medical practices.
2) Provide jacket to minimize contract with sewage.
3) Provide shower facility at the main trailer and require showering
at the end of each shift.
4) Provide separate storage facilities so that employees will not be
forced to wear contaminated clothing home.
Recent events (2)
  • — I (S) $330.00
  • — Z (S) $640.00

1926.21 B06 I

Serious Gravity 08 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $640.00 · Current $330.00 Reduced
Recent events (2)
  • — I (S) $330.00
  • — Z (S) $640.00

1926.59 E01

Other-than-serious Gravity 08 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $640.00
Recent events (2)
  • — I (O)
  • — Z (S) $640.00

View BRYANT ELECTRIC CO.'s full OSHA safety record →