CHICAGO, IL —
OSHA Inspection: DRAPER AND KRAMER, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of DRAPER AND KRAMER, INC. in 641 E. 47TH STREET, CHICAGO, IL 60653 (NAICS 000000). OSHA activity number 122279359.
Where did this inspection happen?
- Establishment
- DRAPER AND KRAMER, INC.
- Site address
- 641 E. 47TH STREET
- City
- CHICAGO
- State
- IL
- ZIP
- 60653
- Mailing
- 641 E. 47TH STREET, CHICAGO, IL 60607
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1542
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $5000.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: %% The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: Prior to the accident which occurred on or about October 23, 1995, the employer (general contractor) did not monitor the subcontractor's compliance with General Note Specification S-1 project drawing, which required that grout for filling reinforced and non-reinforced cells be placed in maximum of 4 foot lifts, and that such cells be fully grouted; and the general contractor did not ensure that the walls were adequately braced. A feasible and useful means of abatement includes, but is not limited to the following actions: 1.Ensure that the general contractor's personnel are properly trained to recognize the standards, work practices and recommendations found in the American Concrete Institute (ACI), the Manual of Concrete Practice (Part 5-1991), the National Concrete Masonry Association (NCMA-TEK), and other recommendations found in Masonry Design And Detailing for grouting and bracing. 2. Ensure that job-specific project drawing specifications are followed. 3. Devise a means of communication between the general contractor and the subcontractor(s) to ensure that safety-related work practices are known, understood and implemented at the job site.
Recent events (2)
- — I (S) $5000.00
- — Z (S) $7000.00
1926.706 B
- Issued
- Abate by
More inspections at DRAPER AND KRAMER, INC.
CHICAGO, IL—2006-03-31 00:00:00
DRAPER AND KRAMER, INC.
CHICAGO, IL—1999-11-08 00:00:00
DRAPER AND KRAMER, INC.
View DRAPER AND KRAMER, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
SCHENECTADY, NY—2012-01-05 00:00:00
BRUCE D. BOWMAN
BILLINGS, MT—2005-01-25 00:00:00
KGC, INC.
ROCKAWAY, NJ—2002-12-31 00:00:00
ROCKAWAY BOROUGH DPW
FOREST CITY, NC—2002-12-31 00:00:00
HARRY BRICKEY DBA A. BRICKEY CEILING COMPANY
EDGERTON, KS—2002-12-31 00:00:00
SUDDEN BOND INDUSTRIES
More inspections in IL
FRANKFORT, IL—2026-07-17 00:00:00
QUANTUM TECHNICAL SERVICES INC.
ROCK ISLAND, IL—2026-07-17 00:00:00
AUGUSTANA COLLEGE
WASHINGTON, IL—2026-07-17 00:00:00
SUNRUN INSTALLATION SERVICES, INC.
FOREST PARK, IL—2026-07-17 00:00:00
CONSERVATION OF SCULPTURE & OBJECTS STUDIO, INC.
BLUE ISLAND, IL—2026-07-17 00:00:00
PROFLOW PUMPING SOLUTIONS
Source