Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: PRECISION STEEL ERECTORS, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of PRECISION STEEL ERECTORS, INC. in PALISADES CENTER RT 59 & 303, WEST NYACK, NY 10994 (NAICS 000000). OSHA activity number 301457198.

Watch Precision Steel Erectors, INC. — free Get an email when a new federal OSHA severe-injury report for Precision Steel Erectors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
PALISADES CENTER RT 59 & 303
City
WEST NYACK
State
NY
ZIP
10994
Mailing
5900 MUDMILL RD., BREWERTON, NY 13029
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
1791
Employees
14
Ownership type
A
Industry flags
Construction safety.

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $3000.00 · Current $3000.00
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to: the collapsing of a steel I-Beam structure that was
"Rough Hung", I-Beam was
not secured by its permanent means, which was to bolt the I-Beam to column
J-7.
Location: Tower 2 Parking Lot Lower level; J-7, I-Beam # W1409B1,
Palisades Center Rt 59
& 303 Nyack NY.
On or About: 12/18/97.
& The employer did not inform all necessary contractors that the I-Beam #
W1409B1 at J-7 was
in a "Rough Hung" condition and the steel 18 inches X 18 inches plate was
not bolted to the
column. Therefore the floor deck at J-7 and J-6 was not ready to receive
the concrete pour.
AMONG OTHER METHODS ONE FEASIBLE AND ACCEPTABLE METHOD TO
CORRECT THIS HAZARD IS:
A) The employer, shall verify by means of a written inspection record,
that all items relating
to the steel erection and steel connections have been accomplished
according to the Framing
Plans and Foundation Plans.
B) The employer, must inform all necessary contractors in writing of any
steel erection items
not accomplished as described in the Foundation Plans and Framing Plans
prior to any concrete
pour.
NOTE: In addition to abatement certification, the employer is required to
submit abatement
documentation for this item in accordance with 29 CFR 1903.19.

1926.104 D

Serious Gravity 02 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $1200.00

1926.502 B04

Serious Gravity 03 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1500.00 · Current $1500.00

1926.501 B14

Serious Gravity 03 1 instance 1 exposed
Issued
Abate by

1926.150 C01 VIII

Other-than-serious Gravity 01 2 instances 1 exposed
Issued
Abate by

1926.452 W02

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Abate by

View PRECISION STEEL ERECTORS, INC.'s full OSHA safety record →

KGC, INC.