DUTCH HARBOR, AK —
OSHA Inspection: OCEAN PEACE, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of OCEAN PEACE, INC. in F/T OCEAN PEACE, DUTCH HARBOR, AK 99692 (NAICS 000000). OSHA activity number 301494670.
Where did this inspection happen?
- Establishment
- OCEAN PEACE, INC.
- Site address
- F/T OCEAN PEACE
- City
- DUTCH HARBOR
- State
- AK
- ZIP
- 99692
- Mailing
- 2601 ELLIOT AVE #4203, SEATTLE, WA 98121
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2092
- Employees
- 55
- Ownership type
- A
- Industry flags
- Maritime safety.
Citations
11 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $1750.00 · Current $578.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of electrical shock, burn or electrocution from unguarded light fixtures and missing snap-ins on the electrical boxes: The following conditions contributed to the existence of these hazards: (a)F/T Ocean Peace: In the change-out room, fluorescent light fixtures, less than 8 feet from the floor, were without covers or protective covers on the tubes. (b)F/T Ocean Peace: In the machine shop, fluorescent light fixtures less than 8 feet from the floor, were without covers or protective covers on the tubes. (c)F/T Ocean Peace: In the engine room, fluorescent light fixtures, less than 8 feet were without covers or protective covers on the tubes. (d)F/T Ocean Peace: In the laundry room, two fluorescent light fixtures, less than 8 feet from the floor, had burned out lights and fluorescent tubes missing. (e)F/T Ocean Peace: In the machine shop, a drilling machine was missing snap-ins on the octagon electrical box and on the electrical switch. (f)F/T Ocean Peace: In the laundry room, the on/off switch box had two snap-ins missing. NOTE: One feasible means of abatement, among others, is to install/replace covers and fluorescent tubes and replace snap-ins.
Recent events (2)
- — F (S) $578.00
- — Z (S) $1750.00
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $1750.00 · Current $577.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of electrical shock, burn or electrocution from the use of ungrounded appliances in the presence of water: The following condition contributed to the existence of this hazard: (a)F/T Ocean Peace: In the galley, a receptacle next to the sink that was not protected with ground-fault circuit-interrupters (GFCI) at either the outlet or the electrical panel. NOTE: One feasible means of abatement, among others, is to install a receptacle or circuit breaker that is protected by a GFCI at each location.
Recent events (2)
- — F (S) $577.00
- — Z (S) $1750.00
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $1000.00 · Current $330.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of electrical shock, burn or electrocution in the case of an electrical emergency when personnel were required to access the panel board: The following condition contributed to the existence of this hazard: (a)F/T Ocean Peace: In the engine room, a 120 volt lighting panel had materials and tools stored in front and was not easily accessible. NOTE: One feasible means of abatement, among others, is to relocate the tools and materials stored in front of the panel.
Recent events (2)
- — F (S) $330.00
- — Z (S) $1000.00
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $1000.00 · Current $330.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to hazard of electrical shock, burn or electrocution from contact with live exposed electrical parts: The following conditions contributed to the existence of these hazards: (a)F/T Ocean Peace: In the laundry room, two hot water heaters had live electrical parts exposed. (b)F/T Ocean Peace: In the galley, a GE pump, model #SKC38NG4289X, 3/4 hp, 3-phase, 115/230V, 3450 rpm had live electrical parts exposed. NOTE: One feasible means of abatement, among others, is to replace the covers on the hot water heaters and the GE pump.
Recent events (2)
- — F (S) $330.00
- — Z (S) $1000.00
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $1750.00 · Current $578.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of electrical shock, burn or electrocution, where exposure to energized equipment while performing any service or maintenance on a machine or equipment and the start up or release of stored energy could occur: (a)F/T Ocean Peace: The employer did not provide written documentation for the control of potentially hazardous energy when employees are engaged in these activities. Among other methods, one feasible and acceptable abatement method to correct this hazard would be to develop and implement a written lockout/tagout program and conduct training to ensure that before any employee performs electrical servicing or maintenance, the machine or equipment is isolated from the energy source and rendered inoperative.
Recent events (2)
- — F (S) $578.00
- — Z (S) $1750.00
1910.38 A01
- Issued
- Abate by
- Penalty
- Initial $1000.00 · Current $330.00 Reduced
Recent events (2)
- — F (S) $330.00
- — Z (S) $1000.00
1910.213 G01
- Issued
- Abate by
- Penalty
- Initial $1750.00 · Current $577.00 Reduced
Recent events (2)
- — F (S) $577.00
- — Z (S) $1750.00
1910.215 A02
- Issued
- Abate by
- Penalty
- Initial $900.00 · Current $300.00 Reduced
Recent events (2)
- — F (S) $300.00
- — Z (S) $900.00
1910.215 A04
- Issued
- Abate by
Recent events (2)
- — F (S)
- — Z (S)
1910.215 B09
- Issued
- Abate by
Recent events (2)
- — F (S)
- — Z (S)
1910.1200 E01
- Issued
- Abate by
Recent events (2)
- — F (O)
- — Z (O)
More inspections at OCEAN PEACE, INC.
DUTCH HARBOR, AK—2026-02-25 00:00:00
OCEAN PEACE, INC
DUTCH HARBOR, AK—2026-02-25 00:00:00
OCEAN PEACE, INC
DUTCH HARBOR, AK—2018-02-09 00:00:00
OCEAN PEACE, INC
DUTCH HARBOR, AK—2018-02-09 00:00:00
OCEAN PEACE, INC
DUTCH HARBOR, AK—2013-02-16 00:00:00
OCEAN PEACE, INC
View OCEAN PEACE, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
SCHENECTADY, NY—2012-01-05 00:00:00
BRUCE D. BOWMAN
BILLINGS, MT—2005-01-25 00:00:00
KGC, INC.
ROCKAWAY, NJ—2002-12-31 00:00:00
ROCKAWAY BOROUGH DPW
FOREST CITY, NC—2002-12-31 00:00:00
HARRY BRICKEY DBA A. BRICKEY CEILING COMPANY
EDGERTON, KS—2002-12-31 00:00:00
SUDDEN BOND INDUSTRIES
More inspections in AK
ANCHORAGE, AK—2026-07-10 00:00:00
AK, INC
ANCHORAGE, AK—2026-07-08 00:00:00
ONE STOP SERVICES
ANCHORAGE, AK—2026-07-08 00:00:00
ANGUS ENTERPRISES
ANCHORAGE, AK—2026-07-08 00:00:00
NORTHERN EXCAVATION & CONSTRUCTION, LLC
UNALASKA, AK—2026-07-07 00:00:00
UNISEA INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 301494670.