EAST HANOVER, NJ —
OSHA Inspection: PUBLIC SERVICE ELECTRIC AND GAS COMPANY
Unprogrammed Related inspection · Health discipline
At a glance
On , OSHA opened an unprogrammed Related health inspection of PUBLIC SERVICE ELECTRIC AND GAS COMPANY in 905 MURRAY ROAD, EAST HANOVER, NJ 07936 (NAICS 000000). OSHA activity number 302132204.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PUBLIC SERVICE ELECTRIC AND GAS COMPANY
- Site address
- 905 MURRAY ROAD
- City
- EAST HANOVER
- State
- NJ
- ZIP
- 07936
- Mailing
- 48 MIDDLE AVENUE, SUMMIT, NJ 07901
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 9631
- Employees
- 76
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Apr 1, 1999
- Abate by
- Apr 13, 1999
- Penalty
- Initial $4,500 · Current $4,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to the employee in that he was exposed to a fall hazard. a) Warehouse, Tri Coastal Design, 905 Murray Road, East Hanover, NJ 07936 A PSE&G employee was raised on a pallet by a forklift truck approximately 12-13 feet to monitor the carbon monoxide levels generated by two ceiling mounted gas powered heaters. The PSE&G employee did not use an appropriate safety platform and was exposed to the hazard of falling 12-13 feet to the concrete floor as fall protection was not provided. Violation occurred on or about 03/19/99. Abatement Notes: Among others, one suitable method for abating this hazardous condition is 1) Utilize only platforms designed for use in elevating personnel with forklifts. These platforms must meet the requirements set forth in ANSI/ASME B56.1-1993. 2) Train all employees about the hazards of falls associated with improper elevating methods, and the proper application and use of safety platforms. This violation requires both certification and documentation as appropriate proof of abatement.
More inspections at Public Service Electric and GAS Company
View Public Service Electric and GAS Company's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 302132204.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.