DEMING, NM —
OSHA Inspection: SISBARRO SUPERSTORE
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SISBARRO SUPERSTORE in OLD HWY 70-80, DEMING, NM 88031 (NAICS 000000). OSHA activity number 303403182.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SISBARRO SUPERSTORE
- Site address
- OLD HWY 70-80
- City
- DEMING
- State
- NM
- ZIP
- 88031
- Mailing
- P.O. BOX 190, DEMING, NM 88031
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 5511
- Employees
- 24
- Ownership type
- A
Citations
5 citations on file for this inspection.
90005 A
- Issued
- Mar 20, 2001
- Abate by
- Apr 16, 2001
- Penalty
- Initial $675 · Current $200 Reduced
General-duty citation text
THE CITATIONS ISSUED ON MARCH 20, 2001, ARE HEREBY AMENDED TO READ: Section 50-9-5(A), NMSA 1978 (New Mexico Occupational Health and Safety Act): Every employer shall furnish to each of his employees employment and a place of employment which are free from recognized hazards that are causing or are likely to cause death or serious physical harm to his employees. A.Employees in the main service area in the center portion of the building are exposed to the hazards associated with the use of schedule 40 PVC pipe for delivery of compressed air. Mode of failure for this type of piping is explosion with sharp projectiles. B.Employees in the engine overhaul area on the east side of the building are exposed to the hazards associated with the use of schedule 40 PVC pipe for delivery of compressed air. Mode of failure for this type of piping is explosion with sharp projectiles. Use of Schedule 40 PVC is contrary to: Sections 842.32, 842.43 and 949.52(b) of American National Standards Institute/American Society of Mechanical Engineers (ANSI/ASME) Standards B31.8-1986, Gas Transmission and Distribution Piping Systems Standards: American Society for Testing Materials (ASTM) D1785-86, Standard Specification for Polyvinyl Chloride Plastic Pipe, Schedules 40, 80, and 120; and ASTM D2513-86a, Standard Specification for Thermoplastic Gas Pressure Piping Systems. Provide a detailed letter explaining means of abatement also include PO number, receipts,and photographs showing needed repairs completed as proof of abatement. Date Corrected Describe Corrective Action :
Recent events (2)
- — A (S) $200.00
- — Z (S) $675.00
1910.37 K02
- Issued
- Mar 20, 2001
- Abate by
- Apr 16, 2001
Recent events (2)
- — A (O)
- — Z (O)
1910.157 E03
- Issued
- Mar 20, 2001
- Abate by
- Apr 16, 2001
Recent events (2)
- — A (O)
- — Z (O)
1910.253 B02 II
- Issued
- Mar 20, 2001
- Abate by
- Apr 16, 2001
Recent events (2)
- — A (O)
- — Z (O)
1910.253 B02 IV
- Issued
- Mar 20, 2001
- Abate by
- Apr 16, 2001
Recent events (2)
- — A (O)
- — Z (O)
More inspections in this industry (NAICS 000000)
More inspections in NM
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 303403182.