ERIE, PA —
OSHA Inspection: PREFABRICATED WALL INSTALLERS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PREFABRICATED WALL INSTALLERS, INC. in 2082 INTERCHANGE ROAD, ERIE, PA 16506 (NAICS 000000). OSHA activity number 303704571.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PREFABRICATED WALL INSTALLERS, INC.
- Site address
- 2082 INTERCHANGE ROAD
- City
- ERIE
- State
- PA
- ZIP
- 16506
- Mailing
- 2623 COMMERCIAL AVENUE, SAN ANTONIO, TX 78221
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1761
- Employees
- 4
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Dec 8, 2000
- Abate by
- Dec 13, 2000
- Penalty
- Initial $375 · Current $240 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employmnent and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to collapse of wood roof trusses: a)Construction Site, Fairfield Inn, 2082 Interchange Road, Erie, PA - Company installing wood roof trusses were not following manufacturers recommendations for temporary bracing. According to manufacturer, HIB- 91, "Recommendations for Handling, Installing and Bracing Metal Plate Connected Wood Trusses", shall be followed for temporary bracing.
Recent events (2)
- — I (S) $240.00
- — Z (S) $375.00
More inspections at Prefabricated Wall Installers, INC.
View Prefabricated Wall Installers, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 303704571.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.