Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: TRENTON PROCESSING CENTER, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TRENTON PROCESSING CENTER, INC. in 120 W BROADWAY, TRENTON, IL 62293 (NAICS 311611). OSHA activity number 309283844.

Watch Trenton Processing Center, INC. — free Get an email when a new federal OSHA severe-injury report for Trenton Processing Center, INC. is published. One employer, no account, unsubscribe in one click.
Site address
120 W BROADWAY
City
TRENTON
State
IL
ZIP
62293
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311611
SIC code (legacy)
2011
Employees
17
Ownership type
A

12 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1500.00 · Current $600.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish to each of his employees employment and a place of employment
which were free
from recognized hazards that were causing or likely to cause death or
serious physical harm
to employees in that employees were exposed to potential inhalation
hazards of ammonia
refrigerant:
On or about 1/12/06 at and around the Machinery Room, employees were
exposed to
potential inhalation hazards of ammonia refrigerant due to:  (1) an alarm
set at a value not
greater than the OSHA PEL (50 ppm) and a detector for ammonia leaks were
not provided in
the Machinery Room, (2) wiring methods did not conform to Class 1,
Division
2, of the
National Electric Code when the employer provided neither continuously run
mechanical
ventilation systems that would actuate alarms upon failure of the
ventilation system, nor
detectors located in areas where ammonia refrigerant from leaks would
concentrate to actuate
alarms and mechanical ventilation systems at 1,000 ppm ammonia, (3)
piping, valves, and
switches controlling ammonia refrigerant flow were not labeled and
identified, (4) signage
with the legend "Machinery Room - Authorized Personnel Only" were not
posted at
entrances to the Machinery Room, (5) schematic drawings or panels giving
directions for the
operation of the ammonia refrigeration system were not provided, and (6)
emergency shut
down procedures were not displayed in the Machinery Room.  Among other
methods, one
feasible and acceptable abatement method to correct the hazardous
conditions would be
adherence to the safe design, installation, and operation of ammonia
refrigeration systems as
prescribed by ANSI/ASHRAE 15 - 2004 Safety Standard for Refrigeration
Systems.
**Abatement documentation required for this item**
Recent events (2)
  • — I (S) $600.00
  • — Z (S) $1500.00

1910.133 A01

Other-than-serious Gravity 02 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $600.00
Recent events (2)
  • — I (O)
  • — Z (S) $600.00

1910.147 C01

Serious Gravity 03 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $750.00 · Current $350.00 Reduced
Recent events (2)
  • — I (S) $350.00
  • — Z (S) $750.00

1910.303 B01

Serious Gravity 02 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $600.00 · Current $240.00 Reduced
Recent events (2)
  • — I (S) $240.00
  • — Z (S) $600.00

1910.303 G02 I

Serious Gravity 03 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $750.00 · Current $350.00 Reduced
Recent events (2)
  • — I (S) $350.00
  • — Z (S) $750.00

1904.4 A

Other-than-serious Gravity 00 1 instance 3 exposed
Issued
Abate by

1910.38 A01

Other-than-serious Gravity 01 1 instance 3 exposed
Issued
Abate by
Recent events (2)
  • — I (O)
  • — Z (O)

1910.303 F

Other-than-serious Gravity 01 1 instance 3 exposed
Issued
Abate by
Recent events (2)
  • — I (O)
  • — Z (O)

1910.305 G01 I

Other-than-serious Gravity 01 1 instance 3 exposed
Issued
Abate by
Recent events (2)
  • — P (O)
  • — Z (O)

1910.305 G02 III

Other-than-serious Gravity 01 1 instance 3 exposed
Issued
Abate by

1910.1200 E01

Other-than-serious Gravity 01 1 instance 3 exposed
Issued
Abate by

1910.1200 H01

Other-than-serious Gravity 01 1 instance 3 exposed
Issued
Abate by

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309283844.