Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: AMERICAN GLASS

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of AMERICAN GLASS in 3799 LAS VEGAS BLVD., SOUTH (MGM), LAS VEGAS, NV 89109 (NAICS 561720). OSHA activity number 312898232.

Watch American Glass — free Get an email when a new federal OSHA severe-injury report for American Glass is published. One employer, no account, unsubscribe in one click.
Establishment
AMERICAN GLASS
Site address
3799 LAS VEGAS BLVD., SOUTH (MGM)
City
LAS VEGAS
State
NV
ZIP
89109
Mailing
2350 SOUTH JONES BLVD., SUITE 6D, LAS VEGAS, NV 89146
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561720
SIC code (legacy)
7349
Employees
5
Ownership type
A
Industry flags
Manufacturing safety.

5 citations on file for this inspection.

618037501

Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
Nevada Revised Statute 618.375(1): The employer failed to furnish employment and
a place of employment which was free from recognized hazards that were causing
or were likely to cause death or serious physical harm to his employees: The emp
loyer failed to furnish employment and a place of employment which was free from
recognized hazards for employees cleaning windows at the MGM GRAND Hotel as fol
lows: a.Prior to accessing the facade of the MGM GRAND Hotel, the building exter
ior was not visually inspected as follows: Two employees from American Glass wer
e observed outside of the west side of the main building performing window washi
ng activities from a swing stage. At the roof level, there was observed several
holes in the edge of the parapet wall, also observed an electrical cord and life
lines in these holes without any padding to protect them from abrasion or cuts.
In addition, the lines from
the swing stage were very close to the gold light fixtures of the MGM GRAND NAME
. Reference: ANSI/IWCA I-14.1-2001, Window Clean Safety, Part A General and Perf
ormance Requirements, Section 5.8.5, "Prior to accessing the facade, the buildin
g exterior shall be visually inspected and, where necessary, appropriate measure
s shall be taken to ensure that building features, such as sharp edges of parape
ts, window frames, open projected windows and cornices or overhangs cannot impai
r the structural integrity of the suspended scaffolding or associated fall prote
ction rigging. These measures shall be incorporated into the work plan in accord
ance with Section 1.7 of this Standard. b.The employer did not, prior to use, in
spect the platform (swing stage). The components of the powered platform, such a
s safety devices, wire ropes, and electrical devices, were not checked for their
general condition as follows:
The electrical cord that powers the stage was found with damaged insulation and
failed strain relief. In addition the electrical cord was observed tied around t
he corner of the swing stage and taped. Reference: ANSI/IWCA I-14.1-2001, Window
Clean Safety, Section 5.9.4, "Prior to use, the platform shall be inspected by
a competent person. Specifically, the components of the powered platform and all
safety devices including motors, brakes, wire rope, stirrups/hangers, decking,
guardrail, electrical devices, rigging equipment, ropes, harnesses, rope grabs a
nd lanyards shall be checked for their general condition. Those components which
have defects shall be immediately removed from service, tagged or marked with a
label which states. "Dangerous, Do Not Use", then restored or destroyed. Improv
ised repairs are prohibited. The unit shall not be used until repairs have been
made and the platform re-inspected.The employees performing the window washing w
ork at the MGM GRAND were exposed to possible serious injuries or death from fal
ls of up to approximately
320 feet to the west roof level below. One feasible means of abatement would be
to ensure that all aspects of the ANSI/IWCA I-14.1-2001 Window Cleaning Safety s
tandard are followed.
Recent events (3)
  • — A (S) $2000
  • — I (S) $1500
  • — Z (S) $2000

1910.305 A02 X

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
Recent events (3)
  • — A (S) $2000
  • — I (S) $1500
  • — Z (S) $2000

1910.305 B01 I

Serious Gravity 04 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
Recent events (3)
  • — A (S) $0
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
Recent events (3)
  • — A (S) $0
  • — I (S) $0
  • — Z (S) $0

618038301

Other-than-serious Gravity 03 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $400.00 · Current $400.00
Recent events (3)
  • — A (O) $400
  • — I (O) $300
  • — Z (O) $400

View AMERICAN GLASS's full OSHA safety record →