Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: PRECAST ERECTORS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PRECAST ERECTORS, INC. in 4502 MEDICAL DRIVE, SAN ANTONIO, TX 78219 (NAICS 236210). OSHA activity number 314305590.

Watch Precast Erectors, INC. — free Get an email when a new federal OSHA severe-injury report for Precast Erectors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4502 MEDICAL DRIVE
City
SAN ANTONIO
State
TX
ZIP
78219
Mailing
P.O. BOX 1748, 3500 VALLEY VISTA DRIVE, HURST, TX 76053
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236210
SIC code (legacy)
1629
Employees
3
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $3675.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazards of being struck by:
a)  On or about 02/14/11, and at times prior there to, employees were
exposed
to being struck by collapsing precasted concrete members.  The employees
were
in the process of erecting the skeleton frame of a North Prow, a 90' x 172'
section of the parking garage.  The employee had erected a portion of this
section
approximately 7 levels high.  During the erection process the employer
failed to
follow the erection notes and ensure that the columns were dry packed
immediately after erection.
b)  On or about 02/14/11, and at times prior there to, employees were
exposed
to being struck by collapsing precasted concrete members.  The employees
were
in the process of erecting the skeleton frame of a North Prow, a 90' x 172'
section of the parking garage.  The employee had erected a portion of this
section
approximately 7 levels high.  During the erection process the employer
failed to
follow the erection notes and ensure that no more than 2 levels were
erected
before columns were fully grouted.
c)  On or about 02/14/11, and at times prior there to, employees were
exposed
to being struck by collapsing precasted concrete members.  The employees
were
in the process of erecting the skeleton frame of a North Prow, a 90' x 172'
section of the parking garage.  The employee had erected a portion of this
section
approximately 7 levels high.  During the erection process the employer
failed to
follow its bracing plan and ensure that the columns were brace in two
directions
at 90 degrees until grouted and tied in with other members.
ABATEMENT NOTE:
Among other methods, one feasible and acceptable abatement is to follow
the erection notes, in
the plans, which specific when to grout and dry pack the column splices.
Also the employer
developed an site specific bracing plan.  The company shall ensure that
they brace the structure
in accordance with the accepted bracing plan.