Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: GUY C. LEE BUILDING MATERIALS, LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of GUY C. LEE BUILDING MATERIALS, LLC in 1251 S. POLLOCK ST., SELMA, NC 27576 (NAICS 321911). OSHA activity number 315450155.

Watch GUY C. LEE Building Materials, LLC — free Get an email when a new federal OSHA severe-injury report for GUY C. LEE Building Materials, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1251 S. POLLOCK ST.
City
SELMA
State
NC
ZIP
27576
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321911
SIC code (legacy)
2431
Employees
9
Ownership type
A
Industry flags
Manufacturing health.

5 citations on file for this inspection.

95012901

Serious 1 instance 11 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1300.00 Reduced
North Carolina General Statute 95-120(1) of the Occupational Safety and
Health Act of North Carolina:  The
employer did not furnish each of his employees conditions of employment
and a place of employment  free from
recognized hazards that were causing or likely to cause death or serious
physical harm to employees in that
employees were exposed to:  fire and explosion hazards due to the
subsequent flame and pressure front that
would be transmitted through the return air ducts into the plant:
a)fabrication shop - where an outdoor dust collector  that captured
combustible class II dust from
employees cutting wood products or particle board that did not meet the
processes and
operations for woodworking facilities on or about July 26, 2011.
Abatement Note:  Among other methods, one feasible and acceptable
abatement method to correct these
hazards was to demolish the discharge duct back into the building and
allow this air to vent outdoors;  to
comply with the National Fire Protections Association (NFPA), 664 standard
for the "Prevention of Fire and
Explosions in Wood Processing and Woodworking Facilities" Chapter 8,
Section 2.2.6 which states, "Recycling
exhaust air shall not be recycled back in the building."  Exceptions are
listed which permit the recycling of
exhaust air:
1.  For collection systems with a capacity less than or equal to 5,000 cfm
(cubic feet per minute) the
system shall be equipped with a spark detection, designed and installed in
conformance of NFPA 72.
2.  For collection systems with a capacity greater than 5,000 cfm (cubic
feet per minute) the collection
system shall be protected by a spark detection system, a high speed abort
gate activated by the spark
detector and the abort gate is provided with a manual resetl
Recent events (2)
  • — F (S) $1300.00
  • — Z (S) $2000.00

1910.22 A01

Serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $600.00 · Current $390.00 Reduced
Recent events (2)
  • — F (S) $390.00
  • — Z (S) $600.00

1910.132 D02

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Recent events (2)
  • — F (O)
  • — Z (O)

1910.157 C01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Recent events (2)
  • — F (O)
  • — Z (O)

1910.1200 E01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Recent events (2)
  • — F (O)
  • — Z (O)

View GUY C. LEE BUILDING MATERIALS, LLC's full OSHA safety record →