Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: DRAGADOS USA/JUDLAU

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of DRAGADOS USA/JUDLAU in 48TH AND MADISON AVENUE (EAST SIDE ACCESS PROJECT), NEW YORK, NY 10017 (NAICS 237310). OSHA activity number 316069400.

Watch Dragados Usa/Judlau — free Get an email when a new federal OSHA severe-injury report for Dragados Usa/Judlau is published. One employer, no account, unsubscribe in one click.
Establishment
DRAGADOS USA/JUDLAU
Site address
48TH AND MADISON AVENUE (EAST SIDE ACCESS PROJECT)
City
NEW YORK
State
NY
ZIP
10017
Mailing
3 EAST 48TH STREET 4TH FLOOR, NEW YORK, NY 10017
Inspection type
Accident-driven (A)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237310
SIC code (legacy)
1622
Employees
800
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $7000.00
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or likely to cause death or serious physical harm to employees in
that employees were
exposed to being struck or crushed by falling concrete.
An employee was walking/working below a section of the tunnel where
sprayed on
concrete was recently applied.  The employee was struck by a piece of
concrete which
dislodged from the ceiling area.
Among other methods, feasible and acceptable abatement methods to correct
the hazards are to:
Comply with ACI 506.2 Specification for Shotcrete section 3 Execution.
Section 3.1 Examination
Verify surfaces are acceptable and ready to receive work.
Verify that surfaces to receive shotcrete have been properly prepared
according
to the Contract Documents.
Section 3.3-Surface Preparation
3.3.2 Concrete, masonry and shotcrete - When bonding is required, remove
all
deteriorated, loose unsound material or contaminants that may inhibit
bonding.
Chip areas to be repaired to remove offsets causing abrupt changes in
thickness.
Taper edges to eliminate square shoulders at the perimeter of a cavity.
Surfaces shall be saturated surface dry immediately prior to shooting.
Comply with MTA directive
The MTA has modified the safe work plan for working with sprayed on
concrete.
The new rule prohibits employees from standing under freshly poured
concrete
for 90 minutes.
NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS
REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM,
FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00
PER 29 CFR 1903.19.0
Recent events (2)
  • — F (S) $7000.00
  • — Z (S) $7000.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 316069400.