Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BIG R SUPPLY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BIG R SUPPLY in 14155 E. HIGHWAY 24, PEYTON, CO 80831 (NAICS 453998). OSHA activity number 330921891.

Watch BIG R Supply — free Get an email when a new federal OSHA severe-injury report for BIG R Supply is published. One employer, no account, unsubscribe in one click.
Establishment
BIG R SUPPLY
Site address
14155 E. HIGHWAY 24
City
PEYTON
State
CO
ZIP
80831
Mailing
14155 E. HIGHWAY 24, PEYTON, CO 80831
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
453998
Employees
32
Ownership type
A

5 citations on file for this inspection.

1910.176 B

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3060.00 · Current $1530.00 Reduced
29 CFR 1910.176(b): Storage of material created a hazard:    a)  On or about July 12, 2011 and at times prior, employees were exposed to hazards associated with storage of material on racks in the feed barn in that, rack columns and footings were bearing on unstable surfaces including cracked and deteriorated pieces of wood.   Rack columns were also not bolted to the floor in the feed barn and receiving area.    Abatement Note: Abatement certification is required for this item. See enclosed Sample Abatement Certification Letter.
Recent events (2)
  • — I (S) $1530
  • — Z (S) $3060

1910.178 P01

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2295.00 · Current $1148.00 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s)    a)  On or about July 12, 2011 and at times prior, a powered industrial truck (Real Lift R-25) in use at the site was in unsafe operating condition in that, it had a broken and non-functional horn.    Abatement Note: Abatement certification is required for this item. See enclosed Sample Abatement Certification Letter.
Recent events (2)
  • — I (S) $1147.5
  • — Z (S) $2295

1910.303 B02

Other-than-serious 1 instance 4 exposed
Issued
Penalty
Initial $1951.00 · Current $976.00 Reduced
29 CFR 1910.303(b)(2):  Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a)  On or about July 12, 2011 and at times prior, a relocatable power tap (power strip) in the customer service area was plugged into another relocatable power tap (power strip) and not into a permanent receptacle as intended.
Recent events (2)
  • — I (O) $975.5
  • — Z (S) $1950.75

1904.29 B01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1904.29(b)(1): A Log of all recordable work-related injuries and illnesses (OSHA Form 300 or equivalent), was not completed in the detail as required by the regulation:    a)  On or about July 12, 2011 and at times prior, the OSHA form 300 logs for 2008, 2010 and 2011 were not completed in sufficient detail specifically as follows:    1.  Both entries for 2008 contained deficiencies as follows: Columns (C) and (E) were left blank.  Column (F) did not contain a description of the injury/illness.  No boxes were checked in columns (G) through (J).    2.  The entry for 2010 contained deficiencies as follows:  Column (E) was left blank.  Column (F) did not contain a description of the injury/illness.  No boxes were checked in columns (G) through (J).    3.  The entry for 2011 contained deficiencies as follows: Column (F) did not contain a description of the injury/illness.  No boxes were checked in columns (G) through (J).    Abatement Note: Abatement certification is required for this item. See enclosed Sample Abatement Certification Letter.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV D

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were attached to building surfaces:    a)  On or about July 12, 2011 and at times prior, the power cord for the compactor was attached to the ceiling and routed to a receptacle on the opposite wall.    Abatement Note: Abatement certification is required for this item. See enclosed Sample Abatement Certification Letter.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View BIG R SUPPLY's full OSHA safety record →