Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: CHIPPEWA BRASS AND ALUMINUM FOUNDRY, LTD.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of CHIPPEWA BRASS AND ALUMINUM FOUNDRY, LTD. in 1350 HALBLEIB ROAD, CHIPPEWA FALLS, WI 54729 (NAICS 331524). OSHA activity number 330924549.

Watch Chippewa Brass AND Aluminum Foundry, LTD. — free Get an email when a new federal OSHA severe-injury report for Chippewa Brass AND Aluminum Foundry, LTD. is published. One employer, no account, unsubscribe in one click.
Site address
1350 HALBLEIB ROAD
City
CHIPPEWA FALLS
State
WI
ZIP
54729
Mailing
1350 HALBLEIB ROAD, CHIPPEWA FALLS, WI 54729
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331524
Employees
5
Ownership type
A

5 citations on file for this inspection.

1910.212 A01

Serious Gravity 1 2 exposed
Issued
Abate by
Penalty
Initial $1530.00 · Current $918.00 Reduced
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operatorand other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips andsparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc.    (a) Grinding/Finishing Area; The conveyor from green-sand storage to the muller was not properly guarded on one-side exposing employees to a nip-point.
Recent events (2)
  • — I (S) $918
  • — Z (S) $1530

1910.1025 E04 I

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1530.00 · Current $918.00 Reduced
29 CFR 1910.1025(e)(4)(i): When ventilation is used to control exposure, measurements which demonstrate the effectiveness of the system in controlling exposure, such as capture velocity, duct velocity, or static pressure shall be made at least every 3 months. Measurements of the system's effectiveness in controlling exposure shall be made within 5 days of any change in production, process, or control which might result in a change in employee exposure to lead.    (a) Throughout the facility; The employer did not conduct evaluations of local exhaust systems to ensure their effectiveness in controlling and reducing exposure to lead and various other substances.
Recent events (2)
  • — I (S) $918
  • — Z (S) $1530

1910.1025 H01

Serious Gravity 1 5 exposed
Issued
Abate by
Penalty
Initial $1530.00 · Current $918.00 Reduced
29 CFR 1910.1025(h)(1): Surfaces. All surfaces shall be maintained as free as practicable of accumulations of lead.    (a) Lunch Area; Wipe sampling indicated lead was found in areas such as, but not limited to, the lunchroom table and the refrigeration door handle.
Recent events (2)
  • — I (S) $918
  • — Z (S) $1530

1910.1025 I04 IV

Serious Gravity 1 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1025(i)(4)(iv): The employer shall assure that employees do not enter lunchroom facilities with protective workclothing or equipment unless surface lead dust has been removed by vacuuming, down draft booth, or other cleaning method.    (a) Lunch area; The employer did not require employees to remove surface lead dust before entering the lunchroom which also served as the change room. Wipe sampling indicated lead was found in areas such as, but not limited to, the lunchroom table and the refrigeration door handle.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1025 F02 I

Other-than-serious 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1025(f)(2)(i): The employer must implement a respiratory protection program in accordance with 1910.134(b) through (d) (except (d)(1)(iii)), and (f) through (m), which covers each employee required by this section to use a respirator.    (a) Throughout the facility; The employer could not find medical evaluations for three of the five employees required to wear NIOSH approved 8210 and 8212 filtering facepiece respirators.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View CHIPPEWA BRASS AND ALUMINUM FOUNDRY, LTD.'s full OSHA safety record →