Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TRADE ONE LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TRADE ONE LLC in 408 SOUTH 1ST AVE, HOLLY, CO 81047 (NAICS 424510). OSHA activity number 330983586.

Watch Trade ONE LLC — free Get an email when a new federal OSHA severe-injury report for Trade ONE LLC is published. One employer, no account, unsubscribe in one click.
Establishment
TRADE ONE LLC
Site address
408 SOUTH 1ST AVE
City
HOLLY
State
CO
ZIP
81047
Mailing
BOX 534, HOLLY, CO 81047
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424510
Employees
3
Ownership type
A

7 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2550.00 · Current $3000.00
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that, employees were exposed to fall hazards:    a) On or about August 9, 2011 and times prior, employees were exposed to serious injuries, in that, the wire rope attachments used as an anchorage for the lifeline were not engineered or evaluated to determine their capacity. This condition was found on the north leg head on the east roof and on the flat storage roof.    Abatement Verification: Abatement certification and documentation is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $3000
  • — Z (S) $2550

1910.23 C01

Serious Gravity 5 5 instances 1 exposed
Issued
Abate by
Penalty
Initial $2040.00 · Current $1000.00 Reduced
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides:    a) On or about August 9, 2011 and times prior, employees were exposed to injuries from falls to the lower surface at the following locations:              1)	South area of the receiving pit lower platform was missing the upper and mid guard rails;            2)	North step landing area was missing the mid guard rail;            3)	North leg head, when accessing the platform to grease the bearing was missing guard rails;            4)	Flat storage northwest roof area platform was missing its guard rails;            5)	Flat storage north to south access platform was missing mid guard rail.    Abatement Verification: Abatement certification and documentation is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2040

1910.219 D01

Serious Gravity 5 3 instances 1 exposed
Issued
Abate by
Penalty
Initial $2040.00 · Current $1000.00 Reduced
29 CFR 1910.219(d)(1):  Pulleys, any part of which are seven (7) feet or less from the floor or working platform, were not guarded in accordance with the standards specified in paragraphs (m) and (o) of this section:    a) On or about August 9, 2011 and times prior, employees were exposed to injuries from unguarded pulleys at the following locations:              1)	North leg head, ventilation fan;              2)	South head house, head pulley;              3)	Flat storage northwest roof area, 2 drive motors.    Abatement Verification: Abatement certification and documentation is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2040

1910.219 E01 I

Serious Gravity 5 3 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(e)(1)(i):  Where runs of horizontal belts are seven (7) feet or less from the floor level, the guard did not extend to at least fifteen (15) inches above the belt or to a standard height:    a) On or about August 9, 2011 and times prior, employees were exposed to injuries from unguarded belts at the following locations:              1)	North leg head, ventilation fan;              2)	South head house, head pulley;              3)	Flat storage northwest roof area, 2 drive motors.    Abatement Verification: Abatement certification and documentation is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.272 G02

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2550.00 · Current $0.00 Reduced
29 CFR 1910.272(g)(2): When entering the grain handling facility bins, silos, or tanks from a level at or above the level of the stored grain, employees did not wear a body harness with lifeline, or use a boatswain's chair that met the requirements of Subpart D, 29 CFR 1910.28(j):    a) On or about August 9, 2011 and times prior, the employer did not ensure that employees were protected from bin entry hazards. Employees were not using a harness and lifeline, or other method of engulfment protection during entry into maxpherson bin #37.    Abatement Verification: Abatement certification and documentation is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $2550

1910.305 B01

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1530.00 · Current $0.00 Reduced
29 CFR 1910.305(b)(1):  Openings through which conductors enter boxes, cabinets, or fittings were not effectively closed:    a) On or about August 9, 2011 and times prior, employees were exposed to injuries, in that, the conduit supplying power to the floodlight was separated exposing the 110-volt conductors to abrasion. The conduit/floodlight was located in the south receiving area next to the wall.    Abatement Verification: Abatement certification and documentation is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $1530

1910.134 F02

Deleted Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(2):  Employees using a tight-fitting facepiece respirator were not fit tested prior to initial use of the respirator, and at least annually thereafter:    a) On or about August 9, 2011 and times prior, employees were exposed to illnesses, in that, the employees were required to wear N-95 respirators prior to being fit tested.    Abatement Note:  Fit testing shall follow the requirements listed in 29 CFR 1910.134(f).    Abatement Verification: Abatement certification and documentation is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View TRADE ONE LLC's full OSHA safety record →