DENVER, CO —
OSHA Inspection: POWER ENGINEERING COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of POWER ENGINEERING COMPANY in 2525 S. DELAWARE ST., DENVER, CO 80223 (NAICS 333999). OSHA activity number 330984790.
Where did this inspection happen?
- Establishment
- POWER ENGINEERING COMPANY
- Site address
- 2525 S. DELAWARE ST.
- City
- DENVER
- State
- CO
- ZIP
- 80223
- Mailing
- 2525 S. DELAWARE ST., DENVER, CO 80223
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333999
- Employees
- 43
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.23 D01
- Issued
- Abate by
- Penalty
- Initial $1785.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.23(d)(1): Open sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standards railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)9i) through (v)), on all open sides except where there is entrance to a ramp, stairway, or fixed ladder: (a) Power Engineering Company at 2525 S Delaware St., Denver, CO 80223: On and before 9/6/11, the employer did not ensure that open sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)9i) through (v)), on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The three air exchangers with open sided platform, eight feet above floor level, was not guarded by standard railings or the equivalent. This condition exposed employees to a fall hazard. (b) Power Engineering Company at 2525 S Delaware St., Denver, CO 80223: On and before 9/6/11, the employer did not ensure that open sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)9i) through (v)), on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The stairway access from the back door of the maintenance shop, was not guarded by standard railings or the equivalent. This condition exposed employees to a fall hazard.
Recent events (2)
- — I (O) $0
- — Z (S) $1785
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $2380.00 · Current $1190.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazards created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Power Engineering Company at 2525 S Delaware St., Denver, CO 80223: On and before 9/6/11, the employer did not protect employees from hazards created by operating a band saw with an unused portion of the blade unguarded, an unguarded trash compactor and a rotating shaft of a table saw motor. This condition exposed employees to amputation and crush hazards. 1) Trash compactor 2) Blue vertical band saw 3) Rotating shaft on the table saw motor Abatement Note: A feasible and acceptable abatement method to correct the hazard includes compliance with the American National Standards Institute, ANSI Z245.2, which requires an operating interlock on door, also an inspection of the trash compactor to ensure the interlock is functioning, and not permit an employee to operate the equipment unless the interlock and gate enclosure is functioning.
Recent events (2)
- — I (S) $1190
- — Z (S) $2380
1910.305 B02 I
- Issued
- Abate by
- Penalty
- Initial $1785.00 · Current $890.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy: (a) Power Engineering Company at 2525 S Delaware St., Denver, CO 80223: On and before 9/6/11, the employer did not protect employees from hazards created by uncovered junction box through which conductors enter. This condition exposed employees to electrical hazards.
Recent events (2)
- — I (S) $890
- — Z (S) $1785
1910.303 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance od such equipment: (a) Power Engineering Company at 2525 S Delaware St., Denver, CO 80223: On and before 9/6/11, the employer did ensure that working space about electric equipment rated 600 volts, nominal, or less had sufficient access to the electrical service panel. This condition exposed employees to electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at POWER ENGINEERING COMPANY
DENVER, CO—2024-08-05 00:00:00
POWER ENGINEERING COMPANY
DENVER, CO—2017-04-07 00:00:00
POWER ENGINEERING COMPANY
DENVER, CO—2017-01-10 00:00:00
POWER ENGINEERING COMPANY
DENVER, CO—2011-09-06 00:00:00
POWER ENGINEERING COMPANY
View POWER ENGINEERING COMPANY's full OSHA safety record →
More inspections in this industry (NAICS 333999)
YAUCO, PR—2026-06-24
SARTORIUS STEDIM FILTERS INC
PLYMOUTH, MI—2026-06-17
SKYWAY PRECISION INC
LEXINGTON, TN—2026-06-17
AUTOMATED MACHINE SPECIALTIES, INC.
ELBERTA, UT—2026-06-17
TAVACI TECHNOLOGIES
PLYMOUTH, MI—2026-06-10
SKYWAY PRECISION INC
More inspections in CO
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
STRASBURG, CO—2026-07-08
JUNIOR ROOFING LLC
FORT COLLINS, CO—2026-07-08
EDWARDS SEMICONDUCTOR SOLUTIONS LLC
CENTENNIAL, CO—2026-07-08
JORDY CONSTRUCTION
HIGHLANDS RANCH, CO—2026-07-08
HOWELL CONSTRUCTION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330984790.