SCARSDALE, NY —
OSHA Inspection: BESTORATION CONTRACTING INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BESTORATION CONTRACTING INC. in 15 FENIMORE RD., SCARSDALE, NY 10583 (NAICS 238160). OSHA activity number 332792563.
Where did this inspection happen?
- Establishment
- BESTORATION CONTRACTING INC.
- Site address
- 15 FENIMORE RD.
- City
- SCARSDALE
- State
- NY
- ZIP
- 10583
- Mailing
- 17 UPLAND DRIVE, GARRISON, NY 10524
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.100 A
- Issued
- Abate by
- Penalty
- Initial $1980.00 · Current $1188.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: location: front of house on or about: 2/27/12 a) Employees, working below a scaffold loaded with slate shingles, were not provided with hard hats. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
- — I (S) $1188
- — Z (S) $1980
1926.451 H02 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: Note: This requirement does not apply to float (ship) scaffolds where an edging of 3/4 inch x 1 1/2 inch (2 x 4 cm) wood or equivalent was used in lieu of toeboards. location: front of house on or about: 2/27/12 a) Employees were working below a scaffold loaded with slate shingles. The scaffold did not have a toeboard. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C02
- Issued
- Abate by
- Penalty
- Initial $1980.00 · Current $1188.00 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: location: front of house on or about: 2/27/12 a) Employees were performing roofing work from tubular welded frame scaffolding. The scaffold, set up in the grass and soil, had base plates but did not rest on mud sills. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
- — I (S) $1188
- — Z (S) $1980
1926.451 G01
- Issued
- Penalty
- Initial $4620.00 · Current $2772.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: location: front of house on or about: 2/27/12 a) Employees, performing roofing work from tubular welded frame scaffolding, were not provided with fall protection. The employees were exposed to a fall between 10'3" and 10'8". NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
- — I (S) $2772
- — Z (S) $4620
1926.454 A
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: location: front of house on or about: 2/27/12 a) Employees were performing roofing work from tubular welded frame scaffolding. The employees were not provided with scaffold safety training. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at BESTORATION CONTRACTING INC.
SCARSDALE, NY—2019-12-04 00:00:00
BESTORATION CONTRACTING INC.
SCARSDALE, NY—2008-01-22 00:00:00
BESTORATION CONTRACTING INC.
View BESTORATION CONTRACTING INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332792563.