Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STEFFANI METALS INCORPORATED

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STEFFANI METALS INCORPORATED in 6811 SATSUMA, HOUSTON, TX 77241 (NAICS 332312). OSHA activity number 333315869.

Watch Steffani Metals Incorporated — free Get an email when a new federal OSHA severe-injury report for Steffani Metals Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
6811 SATSUMA
City
HOUSTON
State
TX
ZIP
77241
Mailing
P.O.BOX 41337, HOUSTON, TX 77241
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
18
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 12 instances 2 exposed
Issued
Abate by
Penalty
Initial $4200.00 · Current $2520.00 Reduced
29 CFR 1910.147(c)(4)(i):  Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:               The employer does not ensure that energy control procedures are developed, documented and implemented to control hazardous energy when employees perform maintenance, servicing, and/or setup on equipment with multiple sources of energy such as electrical, hydraulic, pneumatic and mechianical energy.  The following violations of this occurred on or about March 22, 2012 where employees were exposed to struck-by and caught-in-between hazards when conducting setup and maintenance activities without energy control procedures.    (a) Atlantic Press Brake Area:  1) Atlantic, 150 Ton, Serial 59505, 240 Volts, 60 PSI  2) Atlantic, 200 Ton, Serial 50520, 240 Volts  3) Atlantic, 440 Ton, Serial 7564083938-E, 240 Volts  (b) Sheer Area:    4) Atlantic, 1/4" X 10' , Serial 60015, 240 Volts  5) Atlantic, 3/8 X 13', Serial 645+0, 240 Volts  6) Wysong 1/4" X 10', Serial P37-702, 240 Volts   (c) Roundo Angle Roll Area:   7) R-7-5, Serial 966156, 240 Volts   8) R-5, Serial 915025, 240 Volts   (d) Rouselle Press Area:  9) GI-200, Serial P30428, 240 Volts, 80 PSI   10) 6-A, Serial 24499, 240 Volts, 80 PSI   (e) Fabrication Shop:  11) GEKA Punch, Puma 110H30, Serial 9660, 240 Volts   12) Mubea Ironworker, KBL 1/2, Serial 133-10828-14, 240 Volts
Recent events (2)
  • — I (S) $2520
  • — Z (S) $4200

1910.305 B01 II

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  The employer does not ensure that the electrical junction boxes were effectively closed.  This violation was observed on or about March 22, 2012, in the fabrication shop where the junction box on the Vertical Band Saw, RF916b, was not effectively closed in that it was attached with duct tape.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G02 III

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  The employer does not ensure cords were connected to prevent strain relief from joints or terminal screws. This violatoin was observed on or about March 22, 2012, in fabrication shop, where the cord was separated from the strain relief device on the Hypertherm Plama Cutter Powermax.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View STEFFANI METALS INCORPORATED's full OSHA safety record →