HOUSTON, TX —
OSHA Inspection: STEFFANI METALS INCORPORATED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STEFFANI METALS INCORPORATED in 6811 SATSUMA, HOUSTON, TX 77241 (NAICS 332312). OSHA activity number 333315869.
Where did this inspection happen?
- Establishment
- STEFFANI METALS INCORPORATED
- Site address
- 6811 SATSUMA
- City
- HOUSTON
- State
- TX
- ZIP
- 77241
- Mailing
- P.O.BOX 41337, HOUSTON, TX 77241
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 18
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $4200.00 · Current $2520.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: The employer does not ensure that energy control procedures are developed, documented and implemented to control hazardous energy when employees perform maintenance, servicing, and/or setup on equipment with multiple sources of energy such as electrical, hydraulic, pneumatic and mechianical energy. The following violations of this occurred on or about March 22, 2012 where employees were exposed to struck-by and caught-in-between hazards when conducting setup and maintenance activities without energy control procedures. (a) Atlantic Press Brake Area: 1) Atlantic, 150 Ton, Serial 59505, 240 Volts, 60 PSI 2) Atlantic, 200 Ton, Serial 50520, 240 Volts 3) Atlantic, 440 Ton, Serial 7564083938-E, 240 Volts (b) Sheer Area: 4) Atlantic, 1/4" X 10' , Serial 60015, 240 Volts 5) Atlantic, 3/8 X 13', Serial 645+0, 240 Volts 6) Wysong 1/4" X 10', Serial P37-702, 240 Volts (c) Roundo Angle Roll Area: 7) R-7-5, Serial 966156, 240 Volts 8) R-5, Serial 915025, 240 Volts (d) Rouselle Press Area: 9) GI-200, Serial P30428, 240 Volts, 80 PSI 10) 6-A, Serial 24499, 240 Volts, 80 PSI (e) Fabrication Shop: 11) GEKA Punch, Puma 110H30, Serial 9660, 240 Volts 12) Mubea Ironworker, KBL 1/2, Serial 133-10828-14, 240 Volts
Recent events (2)
- — I (S) $2520
- — Z (S) $4200
1910.305 B01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: The employer does not ensure that the electrical junction boxes were effectively closed. This violation was observed on or about March 22, 2012, in the fabrication shop where the junction box on the Vertical Band Saw, RF916b, was not effectively closed in that it was attached with duct tape.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: The employer does not ensure cords were connected to prevent strain relief from joints or terminal screws. This violatoin was observed on or about March 22, 2012, in fabrication shop, where the cord was separated from the strain relief device on the Hypertherm Plama Cutter Powermax.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at STEFFANI METALS INCORPORATED
HOUSTON, TX—2007-05-15 00:00:00
STEFFANI METALS INCORPORATED
View STEFFANI METALS INCORPORATED's full OSHA safety record →
More inspections in this industry (NAICS 332312)
WYOMING, MI—2026-07-16 00:00:00
R&M FABRICATION LLC
TRUSSVILLE, AL—2026-07-16 00:00:00
ALL SOUTH STEELWORX, LLC
NORTH BRANCH, MN—2026-07-15 00:00:00
111603 - BROWN HAWK LLC DBA NORTHERN LIGHTS STEEL FAB
VAN BUREN, AR—2026-07-14 00:00:00
MILLAR PARTNERS, LLC
CLANTON, AL—2026-07-14 00:00:00
C & S CANOPY, INC.
More inspections in TX
RICHMOND, TX—2026-07-17 00:00:00
CORNELIUS NURSERIES, INC.
HOUSTON, TX—2026-07-17 00:00:00
HOLLOWAY HOUSTON, INC.
BONHAM, TX—2026-07-17 00:00:00
VOLUNTARY PURCHASING GROUPS, INC.
SNYDER, TX—2026-07-16 00:00:00
RNWBL
WICHITA FALLS, TX—2026-07-16 00:00:00
UNITED RENTALS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 333315869.