Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SIGMA FASTENERS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SIGMA FASTENERS, INC. in 16723 ALDINE WESTFIELD, HOUSTON, TX 77032 (NAICS 332710). OSHA activity number 333928620.

Watch Sigma Fasteners, INC. — free Get an email when a new federal OSHA severe-injury report for Sigma Fasteners, INC. is published. One employer, no account, unsubscribe in one click.
Site address
16723 ALDINE WESTFIELD
City
HOUSTON
State
TX
ZIP
77032
Mailing
16723 ALDINE WESTFIELD, HOUSTON, TX 77032
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
47
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $2450.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The employer does not furnish to each of his employees employment and a place of employment which are free from the recognized hazard of being electrically shocked by exposed circuits which are causing or likely to cause death or serious physical harm to employees:  This violation was observed on or about April 18, 2012, in the rear Paint Booth area where employees were exposed to an electrical hazard from using a Shaw-Box hoist pendant control station that was missing a power button exposing the energized electrical circuitry.  Among other feasible methods to correct the identified hazard, one method would be to replace the power button on the pendant control station to prevent inadvertent contact to live electrical parts per ASME B30.16-2007 Overhead hoists (Underhung) Para. 16-1.2.2(c).
Recent events (2)
  • — I (S) $2450
  • — Z (S) $4900

1910.147 C01

Serious Gravity 5 8 instances 5 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $1750.00 Reduced
29 CFR 1910.147(c) (1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.    The employer does not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. This violation occurred on or about April 18, 2012, in the shop area where employees were exposed to electrical and struck-by hazards when they were allowed to perform service and/or maintenance including set-up on manual lathes, vertical mills, heat treating ovens, threading machines, band saws, and hydraulic presses. A hazardous energy program to control the release of stored energy for machinery with multiple sources had not been established and implemented.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

View SIGMA FASTENERS, INC.'s full OSHA safety record →