BUFFALO, NY —
OSHA Inspection: ROCHESTER DAVIS-FETCH CORP.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ROCHESTER DAVIS-FETCH CORP. in ELLICOTT ST. AND GOODRICH ST., BUFFALO, NY 14210 (NAICS 238310). OSHA activity number 333959229.
Where did this inspection happen?
- Establishment
- ROCHESTER DAVIS-FETCH CORP.
- Site address
- ELLICOTT ST. AND GOODRICH ST.
- City
- BUFFALO
- State
- NY
- ZIP
- 14210
- Mailing
- 175 DODGE STREET, ROCHESTER, NY 14606
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 26
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.404 B01 I
- Issued
- Penalty
- Initial $3060.00 · Current $3060.00
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. a) On or about 4/16/12 and 4/17/12 on the 6th floor near column E-3 at bridge, on construction site at Ellicott & Goodrich Streets (UB Space Build-out), Buffalo, NY: A large portable fan used to dry a wall after taping was connected to 110-volt ac power via an extension cord which was plugged into a receptacle in the nearby hallway. No GFCI or assured equipment grounding program was being used. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $3060
- — Z (S) $3060
1926.404 F06
- Issued
- Penalty
- Initial $3060.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) On or about 4/16/12 and 4/17/12 on the 6th floor near column E-3 at bridge, on construction site at Ellicott & Goodrich Streets (UB Space Build-out), Buffalo, NY: The plug on the cord of a large portable fan used to dry a wall after taping lacked a ground prong. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $3060
More inspections at ROCHESTER DAVIS-FETCH CORP.
LANCASTER, NY—2015-08-13 00:00:00
ROCHESTER DAVIS-FETCH CORP.
ROCHESTER, NY—2012-08-02 00:00:00
ROCHESTER DAVIS-FETCH CORP.
BUFFALO, NY—2011-11-30 00:00:00
ROCHESTER DAVIS-FETCH CORP
ROCHESTER, NY—2011-06-22 00:00:00
ROCHESTER DAVIS-FETCH CORP.
AMHERST, NY—2010-08-19 00:00:00
ROCHESTER DAVIS-FETCH CORP
View ROCHESTER DAVIS-FETCH CORP.'s full OSHA safety record →
More inspections in this industry (NAICS 238310)
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
NAMPA, ID—2026-07-15
INTERIOR SYSTEMS, INC.
BRIDGEPORT, WV—2026-07-14
EASLEY & RIVERS, INC.
ELLETTSVILLE, IN—2026-07-13
ENVIRO HEAT, LLC
ELLETTSVILLE, IN—2026-07-13
RWS INSULATION SERVICES, LLC
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source