MARYVILLE, MO —
OSHA Inspection: ROBERTS ROOFING CO., INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ROBERTS ROOFING CO., INC. in MAIN STREET, MARYVILLE, MO 64468 (NAICS 238160). OSHA activity number 334175049.
Where did this inspection happen?
- Establishment
- ROBERTS ROOFING CO., INC.
- Site address
- MAIN STREET
- City
- MARYVILLE
- State
- MO
- ZIP
- 64468
- Mailing
- 1601 BUCHANAN AVENUE, SAINT JOSEPH, MO 64501
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 15
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.100 A
- Issued
- Penalty
- Initial $1200.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets. On 12 April, 2012 at the job site located on Main Street in Maryville, MO employees were exposed to head injury from flying objects in that they working on the ground with no protective helmets while work was going on overhead producing falling and flying objects.
Recent events (2)
- — I (S) $0
- — Z (S) $1200
1926.150 C01 VI
- Issued
- Penalty
- Initial $1600.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, shall be provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas are being used on the jobsite. This requirement does not apply to the integral fuel tanks of motor vehicles. On 12 April, 2012 at the jobsite located on Main Street in Maryville, MO employees were exposed to a fire hazard in that they were using a propane torch without having a fire extinguisher on site.
Recent events (2)
- — I (S) $0
- — Z (S) $1600
1926.501 B10
- Issued
- Penalty
- Initial $2800.00 · Current $1960.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted. On April 12, 2012 at the jobsite located on Main Street in Maryville, MO employees were exposed to fall from height hazards in that they were working on roof structure approximately 38 feet above ground level without the use of an approved fall protection system.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1926.1053 B01
- Issued
- Penalty
- Initial $1200.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.
Recent events (2)
- — I (S) $0
- — Z (S) $1200
More inspections at ROBERTS ROOFING CO., INC.
SAINT JOSEPH, MO—2016-06-09 00:00:00
ROBERTS ROOFING CO., INC.
TRENTON, MO—2015-07-14 00:00:00
ROBERTS ROOFING CO., INC.
MARYVILLE, MO—2012-04-27 00:00:00
ROBERTS ROOFING CO., INC.
GOWER, MO—2007-11-27 00:00:00
ROBERTS ROOFING CO., INC.
ST. JOSEPH, MO—2007-10-09 00:00:00
ROBERTS ROOFING CO., INC.
View ROBERTS ROOFING CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in MO
KANSAS CITY, MO—2026-07-09
NIAGARA BOTTLING
MONETT, MO—2026-07-09
MONETT METALS INC.
PARKVILLE, MO—2026-07-08
SKY-TECH ROOFING, LLC.
SPRINGFIELD, MO—2026-07-07
D & C CONSTRUCTION, LLC.
JOPLIN, MO—2026-07-07
SERVICE RECYCLING - NORTH PLANT