Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HORIZONTAL WELL DRILLERS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of HORIZONTAL WELL DRILLERS in HWY 281, JACKSBORO, TX 76458 (NAICS 213111). OSHA activity number 334249919.

Watch Horizontal Well Drillers — free Get an email when a new federal OSHA severe-injury report for Horizontal Well Drillers is published. One employer, no account, unsubscribe in one click.
Site address
HWY 281
City
JACKSBORO
State
TX
ZIP
76458
Mailing
2915 STATE HWY 74 SOUTH, PURCELL, OK 73080
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
Employees
450
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $4000.00 · Current $7000.00
OSH ACT of 1970 Section (5)(a)(1):  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to electrical shock hazards.      On or about May 10, 2012 at the work site located at Horizontal Well Drilling Rig #2, HWY 281 Jacksboro, Texas: the employer did not ensure that all trailers including but not limited to the Shale Shaker Trailer were grounded.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $4000

5(a)(1)

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $25000.00 · Current $7000.00 Reduced
OSH ACT of 1970 Section (5)(a)(1):  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall hazards.      On or about May 10, 2012 at the work site located at Horizontal Well Drilling Rig #2, HWY 281 Jacksboro, Texas:  employees assigned to work on the monkey board were not provided an adequate means of safe egress from the work platform exposing employees to fractures, burns, and death.      HORIZONTAL WELL DRILLERS WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 5(a)(1), WHICH IS CONTAINED IN OSHA INSPECTION 311872816, CITATION NUMBER 001, ITEM 2, ISSUED APRIL 2, 2009, WITH RESPECT TO A WORKPLACE LOCATED AT PUNXY HC 3H, LAWRENCE TWP, CLEARFIELD CNTY, PENFIELD, PA.
Recent events (2)
  • — I (S) $7000
  • — Z (R) $25000

1910.23 C01

Serious Gravity 1 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $15000.00 · Current $7000.00 Reduced
29 CFR 1910.23(c)(1):  Open-sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides.      On or about May 10, 2012, at the work site located at Horizontal Well Drilling Rig #2, HWY 281 Jacksboro, Texas:  a section of the top rail and mid rail were missing on the drill deck  leaving an opening of approximately 24 inches exposing employees to a fall hazard of more than 12 feet.        HORIZONTAL WELL DRILLERS WAS PREVIOULSY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.23(c), WHICH IS CONTAINED IN OSHA INSPECTION NUMBER 314157884, CITATION NUMBER 1, ITEM 2, ISSUED OCTOBER 20, 2010.
Recent events (2)
  • — I (S) $7000
  • — Z (R) $15000

1910.132 A

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $27500.00 · Current $7000.00 Reduced
29 CFR 1910.132(a):  Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered.      On or about May 10, 2012, at the work site located at Horizontal Well Drilling Rig #2, HWY 281 Jacksboro, Texas:  the employer did not ensure that the employees wore Personal Protection Equipment while engaged in oil and gas drilling activities.  The employees did not have on Flame-Resistant Clothing (FRC) exposing employees to flash fires.      HORIZONTAL WELL DRILLERS WAS PREVIOULSY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.132(a), WHICH IS CONTAINED IN OSHA INSPECTION NUMBER 313373540, CITATION NUMBER 1, ITEM 2, ISSUED AUGUST 11, 2010.
Recent events (2)
  • — I (S) $7000
  • — Z (R) $27500

View HORIZONTAL WELL DRILLERS's full OSHA safety record →