Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CHERRY HILL CONSTRUCTION COMPANY INC.

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of CHERRY HILL CONSTRUCTION COMPANY INC. in 51 CIRO ROAD, NORTH BRANFORD, CT 06471 (NAICS 238910). OSHA activity number 334530789.

Watch Cherry Hill Construction Company INC. — free Get an email when a new federal OSHA severe-injury report for Cherry Hill Construction Company INC. is published. One employer, no account, unsubscribe in one click.
Site address
51 CIRO ROAD
City
NORTH BRANFORD
State
CT
ZIP
06471
Mailing
51 CIRO ROAD, NORTH BRANFORD, CT 06471
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
120
Ownership type
A

9 citations on file for this inspection.

1910.157 E01

Other-than-serious 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2970.00 · Current $1782.00 Reduced
29 CFR 1910.157(e)(1):  The employer shall be responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace:  Establishment:  The employer did not ensure that the inspection, maintenance and testing of all portable fire extinguishers in the workplace were completed and updated.
Recent events (2)
  • — I (O) $1782
  • — Z (S) $2970

1910.253 B02 II

Serious Gravity 5 10 instances 20 exposed
Issued
Abate by
Penalty
Initial $3960.00 · Current $3960.00
29 CFR 1910.253(b)(2)(ii):  Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior:  Welding shop:  The employer did not ensure that the gas cylinders, used for welding operations were stored within well-protected, well-ventilated and appropriate storage areas maintining safe distance from highly combustible materials to protect them from being knocked over, damaged by passing, falling objects, or subject to tampering by unauthorized persons.
Recent events (2)
  • — I (S) $3960
  • — Z (S) $3960

1910.253 B02 IV

Serious Gravity 5 3 instances 20 exposed
Issued
Abate by
Penalty
Initial $3960.00 · Current $0.00 Reduced
29 CFR 1910.253(b)(2)(iv):  Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:  Welding Shop: the employer did not ensure that valve protection caps were always in place and hand-tight, except when cylinders were in use or connected for use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3960

1910.253 B04 III

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $3960.00 · Current $0.00 Reduced
29 CFR 1910.253(b)(4)(iii):  Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.  Welding Shop:  The employer did not ensure that the oxygen cylinders in storage were separated from fuel-gas cylinders or combustible materials by a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet high and having a appropriate fire-resistance rating.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3960

1910.303 B02

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $4950.00 · Current $4950.00
29 CFR 1910.303(b)(2):  Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Welding Shop; Two junction boxes were connected to two flexible cords, one was used as a 4 gang outlet box and the second was a single to 220 volt plug for the TIG welder were not installed and used in accordance with its listing and labeling.
Recent events (2)
  • — I (S) $4950
  • — Z (S) $4950

1910.304 F01 IV

Serious Gravity 5 6 instances 2 exposed
Issued
Abate by
Penalty
Initial $3960.00 · Current $0.00 Reduced
29 CFR 1910.304(f)(1)(iv):  Overcurrent devices for circuits rated 600 volts, nominal, or less were located where they were exposed to physical damage or in the vicinity of easily ignitable material  Welding Shop; The circut pannel, control boxes and other electrical equipment that provided over current protection was exposed to physical damage from the rolling metal scrap dumpster and was in close proximity to ignitable material.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3960

1910.303 G02 I

Serious Gravity 5 3 instances 2 exposed
Issued
Abate by
Penalty
Initial $3960.00 · Current $0.00 Reduced
29 CFR 1910.303(g)(2)(i):  Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  Welding Shop; Employees were exposed to potential electric shock hazards from the 120/208 volt electrical distribution panel that was missing circuit breakers.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3960

1910.1200 H01

Repeat Gravity 5 1 instance 20 exposed
Issued
Penalty
Initial $7920.00 · Current $4752.00 Reduced
29 CFR 1910.1200(h)(1):  Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  Establishment;  The employees, required to work with and handle chemicals, such as (but not limited to) Oils, degreasers, fuel additives, break fluids, and welding gasses were not provided with the information and training in the Hazard Communication program.    Cherry Hill Construction was previously cited for a violation of this Occupational Safety and Health standard 29 CFR 1910.1200(h)(1), which was contained in OSHA inspection number 123193094, citation number 1, item number 7b and was affirmed as a final order on 12/30/11, with respect to a workplace located at 51Ciro Road North Branford CT  06471.
Recent events (2)
  • — I (R) $4752
  • — Z (R) $7920

1910.184 E03 II

Other-than-serious 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.184(e)(3)(ii): Records of the most recent month in which each alloy steel chain sling was thoroughly inspected were not available for examination:    Establishment:  The employer did notl make a record of the most recent month in which each alloy steel chain sling was thoroughly inspected available for examination.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View CHERRY HILL CONSTRUCTION COMPANY INC.'s full OSHA safety record →