TAMPA, FL —
OSHA Inspection: CORROSION CONTROL SPECIALISTS, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of CORROSION CONTROL SPECIALISTS, INC. in 1700 HEMLOCK STEET, TAMPA, FL 33605 (NAICS 238990). OSHA activity number 334537537.
Where did this inspection happen?
- Establishment
- CORROSION CONTROL SPECIALISTS, INC.
- Site address
- 1700 HEMLOCK STEET
- City
- TAMPA
- State
- FL
- ZIP
- 33605
- Mailing
- P. O. BOX 3146, RIVERVIEW, FL 33569
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 20
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.1025 D02
- Issued
- Penalty
- Initial $2000.00 · Current $1300.00 Reduced
General-duty citation text
29 CFR 1910.1025(d)(2): An initial determination was not made to determine if any employee may be exposed to lead at or above the action level: a. At the establishment located on 1650 Hmlock St., Tampa, FL, employees performing lead paint removal, with the use of a needle gun system, in the lower deck of the US Coast Guard, VISE, vessel, were exposed to the health hazards associated with lead. No initial determination had been performed, on or about, 05/23/2012.
Recent events (2)
- — I (S) $1300
- — Z (S) $2000
1910.1025 D07
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1025(d)(7): Additional exposure monitoring was not conducted when there was a change in production, process, control or personnel, or any other reason to suspect a change that may have resulted in new or additional exposure to lead: a. At the establishment located on 1650 Hmlock St., Tampa, FL, employees performing lead paint removal in the lower deck of the US Coast Guard, VISE, vessel, were exposed to the health hazards associated with lead. The removal process was changed from a needle gun system, to a sandblasting operation. No initial determination was performed, on or about, 06/11/2012.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.95 B01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1300.00 Reduced
8110
General-duty citation text
29 CFR 1910.95(b)(1): When employees were subjected to sound exceeding those listed in Table G-16, feasible administrative or engineering controls were not utilized: a. At the establishment located on 1650 Hemlock St., Tampa, FL, employees using a needle gun system while performing lead paint removal, in the lower deck of the US Coast Guard, VISE vessel, were being exposed to continuous noise levels at 684% and 954% of the allowable 8-hour time-weighted sound level (90 dbA). The equivalent dbA level of 684% is approximately 104.3 dbA, and for 954%, is approximately 106.6 dbA. The employee exposed to 684% was sampled for a period of 455 minutes, while the other employee, exposed to 954%, was sampled for a period of 462 minutes. Both employees were sampled during one shift on 05/31/2012 and were observed wearing hearing protection. ABATEMENT NOTES: General methods of control applicable in these circumstances include, but may not be limited to, the following: 1. Installation of noise absorbing / attenuation materials around the operators and/or material. 2. The use of a low vibration needle / chisel scalers. 3. Employee rotation. MULTI-STEP ABATEMENT PROCEDURES: STEP 1: Due- (45 days from issue) An effective hearing conservation program must be maintained as per Citation 1, Item 1(b) STEP 2: Due (90 days from issue) A written detailed plan of abatement shall be submitted to the Area Director outlining a schedule for the implementation of engineering and/or administrative measures to control employee exposure to noise as referenced in this citation. The plan shall include, at a minimum, target dates for the following actions which must be consistent with the dates required by this citation: 1. Evaluation of engineering / administrative control options; 2. Selection of optimum control methods and completion design; 3. Procurement, installation and operations of selected control measures; 4. Testing and acceptance or modifications / redesign of controls. All control measures shall be evaluated for each particular use by a competent industrial hygienist or other technically qualified person. 45 days reports are required during the abatement period.
Recent events (2)
- — I (S) $1300
- — Z (S) $2000
1910.95 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
8111
General-duty citation text
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: a. At the establishment located on 1650 Hemlock St., Tampa, FL, employees using a needle gun system while performing lead paint removal, in the lower deck of the US Coast Guard, VISE vessel, were being exposed to continuous noise levels at 684% and 954% of the allowable 8-hour time-weighted sound level (90 dbA). The equivalent dbA level of 684% is approximately 104.3 dbA, and for 954%, is approximately 106.6 dbA. The employee exposed to 684% was sampled for a period of 455 minutes, while the other employee, exposed to 954%, was sampled for a period of 462 minutes. Both employees were sampled during one shift on 05/31/2012 and were observed wearing hearing protection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 E01
- Issued
- Penalty
- Initial $200.00 · Current $200.00
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a. At the establishment located on 1650 Hemlock St., Tampa, FL, employees wearing 3M, half-face, respirator with dual HEPA filters, while performing paint removal in the lower deck of the US Coast Guard, VISE vessel, were being exposed to the health hazards associated with lead. No medical evaluation had not been provided, on or about, 05/23/2012. Corrosion Control Specialists, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard or its equivalent standard 29 CFR 1910.134(e)(1), which was contained in OSHA inspection number 315883421, citation number 2, item 1, and was affirmed as a final order on 01/14/2012, with respect to the workplace located at Gulf Marine, Tampa, FL.
Recent events (2)
- — I (R) $200
- — Z (R) $200
1910.134 G01 I A
- Issued
- Penalty
- Initial $200.00 · Current $200.00
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: a. At the establishment located on 1650 Hemlock St., Tampa, FL, employees wearing 3M, half-face, respirators with dual HEPA filters, while performing paint removal in the lower deck of the US Coast Guard, VISE vessel, were being exposed to the health hazards associated with lead. Employees wearing facial hair was observed, on or about, 05/23/2012. Corrosion Control Specialists, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard or its equivalent standard 29 CFR 1910.134(e)(1), which was contained in OSHA inspection number 315883421, citation number 2, item 3, and was affirmed as a final order on 01/14/2012, with respect to the workplace located at Gulf Marine, Tampa, FL.
Recent events (2)
- — I (R) $200
- — Z (R) $200
More inspections at CORROSION CONTROL SPECIALISTS, INC.
BAYONNE, NJ—2022-01-21 00:00:00
CORROSION CONTROL SPECIALISTS, INC.
BAYONNE, NJ—2021-12-28 00:00:00
CORROSION CONTROL SPECIALISTS, INC.
BAYONNE, NJ—2020-10-04 00:00:00
CORROSION CONTROL SPECIALISTS, INC.
MOBILE, AL—2016-05-23 00:00:00
CORROSION CONTROL SPECIALISTS, INC.
MOBILE, AL—2014-05-19 00:00:00
CORROSION CONTROL SPECIALISTS, INC
View CORROSION CONTROL SPECIALISTS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238990)
ZEPHYRHILLS, FL—2026-07-14
PERIMETER SOLUTIONS GROUP FLORIDA, LLC
NEW YORK, NY—2026-07-09
PALM INDUSTRIES LLC
NEW YORK, NY—2026-07-09
PALM INDUSTRIES LLC
EL PASO, TX—2026-07-09
RM CRANE & RIGGING LLC.
LAKEWOOD, WA—2026-07-08
WA317992018 - HARMON INC DBA HARMON SERVICE GLAZING INC
More inspections in FL
MARIANNA, FL—2026-07-16
BRANNON BROTHERS CONSTRUCTION, LLC
LAKELAND, FL—2026-07-16
SOUTHERN MILLING & LUMBER, INC.
OAKLAND PARK, FL—2026-07-16
PKB CABINETRY
LAKELAND, FL—2026-07-16
ELIJAH WHOLESALE, LLC.
TAMPA, FL—2026-07-16
VALENCIA WHOLESALE, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334537537.