KEYPORT, NJ —
OSHA Inspection: FRAGRANCE RESOURCES INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of FRAGRANCE RESOURCES INC. in 275 CLARK STREET, KEYPORT, NJ 08078 (NAICS 325998). OSHA activity number 334670981.
Where did this inspection happen?
- Establishment
- FRAGRANCE RESOURCES INC.
- Site address
- 275 CLARK STREET
- City
- KEYPORT
- State
- NJ
- ZIP
- 08078
- Mailing
- 275 CLARK STREET, KEYPORT, NJ 08078
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325998
- Employees
- 38
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.119 D02 I A
- Issued
- Aug 17, 2012
- Abate by
- Sep 17, 2012
- Penalty
- Initial $1,785 · Current $893 Reduced
General-duty citation text
29 CFR 1910.119(d)(2)(i)(A): The process safety information did not include information pertaining to the technology of the process inicluding a block flow diagram or a simplified process flow diagram: a) Solutions and blending facility: The employer did not develop a block flow diagram for over 10,000 pounds of ethanol used to make solutions for perfumes and colognes, on or about 6/11/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $892.5
- — Z (S) $1785
1910.119 D03 I B
- Issued
- Aug 17, 2012
- Abate by
- Sep 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(d)(3)(i)(B): The employer's piping and instrument diagrams were not accurate and did not represent equipment that was existing and was part of the process. a) Solutions and blending facility: The piping and instrument diagram was not updated to show that the 39C ethanol was changed to 40B and that both ethanol tanks were currently known as 40B, on or about 6/11/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.119 O01
- Issued
- Aug 17, 2012
- Abate by
- Nov 12, 2012
- Penalty
- Initial $1,785 · Current $893 Reduced
General-duty citation text
29 CFR 1910.119(o)(1): The employer did not certify that they have evaluated compliance with the provisions of this section at least every three years: a) Solutions and blending facility: The employer did not conduct a compliance audit at least once every three years to verify that the procedures and practices developed under the standard were adequate and being followed, on or about 6/11/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $892.5
- — Z (S) $1785
More inspections at Fragrance Resources INC.
View Fragrance Resources INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325998)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334670981.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.