CHARLESTON, WV —
OSHA Inspection: TRG CUSTOMER SOLUTIONS
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of TRG CUSTOMER SOLUTIONS in 100 PARKWAY ROAD, CHARLESTON, WV 25309 (NAICS 561499). OSHA activity number 335067385.
Where did this inspection happen?
- Establishment
- TRG CUSTOMER SOLUTIONS
- Site address
- 100 PARKWAY ROAD
- City
- CHARLESTON
- State
- WV
- ZIP
- 25309
- Mailing
- 100 PARKWAY ROAD, CHARLESTON, WV 25309
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561499
- Employees
- 350
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.157 G01
- Issued
- Abate by
- Penalty
- Initial $2700.00 · Current $1890.00 Reduced
General-duty citation text
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting: (a) Maintenance personnel who are responsible for using portable ABC fire extinguishers have not been through a training program on the safe use of fire extinguishers and the hazards of incipient stage fires as determined on July 9, 2012. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1890
- — Z (S) $2700
1910.303 F02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: (a) Electrical Room: A circuit breaker box was not labeled to indicate what each breaker inside was connected to or marked with a blue print designation number as was done with the other breaker boxes in the room as was observed on July 9, 2012. ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- — Z (O) $0
1910.157 E03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: (a) Portable ABC fire extinguishers that were available for use on site were six months past their due date for an annual maintenance check as observed on July 9, 2012. ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- — Z (O) $0
More inspections at TRG CUSTOMER SOLUTIONS
CHARLESTON, WV—2009-05-07 00:00:00
TRG CUSTOMER SOLUTIONS
View TRG CUSTOMER SOLUTIONS's full OSHA safety record →
More inspections in this industry (NAICS 561499)
PRINEVILLE, OR—2026-06-26
317744630 - CENTRAL OREGON PROCESSING LLC
WINDSOR, CT—2026-02-13
IRON MOUNTAIN
ANCHORAGE, AK—2026-01-30
GREAT ORIGINALS, INC.
ERLANGER, KY—2025-11-20
68601 - CONDUENT COMMERCIAL SOLUTIONS LLC
LODI, CA—2025-10-09
LODI UNIFIED SCHOOL DISTRICT
More inspections in WV
CHARLESTON, WV—2026-07-15
ASTECH CORPORATION
PARKERSBURG, WV—2026-07-15
UNKNOWN
VIENNA, WV—2026-07-15
PHOENIX ASSOCIATES, INC.
BRIDGEPORT, WV—2026-07-14
MID ATLANTIC METALWORKS INC.
BRIDGEPORT, WV—2026-07-14
INFINITY ELECTRIC & SERVICE COMPANY, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335067385.