PERRY, FL —
OSHA Inspection: BIG TOP TRAMPOLINE, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BIG TOP TRAMPOLINE, INC. in 3255 N US-19, PERRY, FL 32347 (NAICS 332311). OSHA activity number 335316584.
Where did this inspection happen?
- Establishment
- BIG TOP TRAMPOLINE, INC.
- Site address
- 3255 N US-19
- City
- PERRY
- State
- FL
- ZIP
- 32347
- Mailing
- 3255 N US-19, PERRY, FL 32347
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332311
- Employees
- 84
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $1785.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: a. On or about July 18, 2012, employees, servicing equipment throughout the manufacturing area, were exposed to hazards resulting from the unexpected release of stored energy because the employer did not have clear and specific written energy control procedures that outlined the scope, rules and steps for the control of hazardous energy for various machines, such as but not limited to the Ficep A 164T machine.
Recent events (2)
- — I (S) $1785
- — Z (S) $2975
1910.215 A04
- Issued
- Penalty
- Initial $1785.00 · Current $1071.00 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a. On or about July 18, 2012, in the FICEP area, employees were using the Dayton 10-inch Bench Grinder to grind steel pieces with the work rest adjusted approximately 3/8-inches away from the grinding wheel, exposing themselves to struck-by hazards.
Recent events (2)
- — I (S) $1071
- — Z (S) $1785
1910.215 B09
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a. On or about July 18, 2012, in the FICEP area, employees using the Dayton 10-inch Bench Grinder to grind metal pieces had the adjustable tongue for the left grinding wheel 1 inch away from the grinding wheel, exposing themselves to struck-by hazards. b. On or about July 18, 2012, in the FICEP area, employees using the Dayton 10-inch Bench Grinder to grind metal pieces had the adjustable tongue for the right grinding wheel 1-3/16 inches away from the grinding wheel, exposing themselves to struck-by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.215 D03
- Issued
- Penalty
- Initial $1785.00 · Current $1071.00 Reduced
General-duty citation text
29 CFR 1910.215(d)(3): The contact surface(s) of wheel(s), blotter(s) or flange(s) on grinding machine(s) were not flat and free or foreign matter: a. On or about July 18, 2012, in the FICEP area, the employer did not ensure that the two grinding wheels used on the Dayton 10-inch Bench Grinder had flat contact surfaces. Both grinding stones were grooved by the parts being grinded, and exposed the employees to struck-by hazards.
Recent events (2)
- — I (S) $1071
- — Z (S) $1785
1910.303 E01 II
- Issued
- Penalty
- Initial $2380.00 · Current $1428.00 Reduced
General-duty citation text
29 CFR 1910.303(e)(1)(ii): Markings were not provided on electrical equipment giving voltage, current, wattage and other markings as necessary: a. On or about July 18, 2012, in the Vinyl Forming area, the electrical panels and cabinets did not have markings indicating the voltage, current, wattage or other markings. b. On or about July 18, 2012, in the Steel Forming area, the electrical panels and cabinets did not have markings indicating voltage, current, wattage or other markings.
Recent events (2)
- — I (S) $1428
- — Z (S) $2380
1910.303 F02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a. On or about July 18, 2012, in the Vinyl Forming area, the electric panel on the east wall had circuit breakers #2 and #10 in the ON position and the breakers were not marked to indicate their purpose. b. On or about July 18, 2012, in the Vinyl Forming area and Steel Forming area, the on/off switch panels for the Siemens Fiab HF AB, Forsstrom HF machines, Weld Master Miller 112 and the VS-355AC semi-automatic saw, among other equipment, were not marked to indicate their purpose.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Penalty
- Initial $2380.00 · Current $1428.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a. On or about July 18, 2012, in the Vinyl Forming area, the electric panel on the east wall had an unused circuit-breaker knockout that was not effectively closed and the metal bus bar was visible, exposing employees to electrical hazards.
Recent events (2)
- — I (S) $1428
- — Z (S) $2380
1910.157 E03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: a. On or about July 18, 2012, throughout the manufacturing area, the employer did not ensure that portable fire extinguishers were subjected to an annual maintenance check.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.212 B
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a. On or about July 18, 2012, in the FICEP area, employees grinding steel parts were using a Dayton 10-inch bench grinder on a stand that had not been anchored to the ground, exposing themselves to struck-by injuries.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at BIG TOP TRAMPOLINE, INC.
PERRY, FL—2025-07-01 00:00:00
BIG TOP TRAMPOLINE, INC.
PERRY, FL—2013-01-23 00:00:00
BIG TOP TRAMPOLINE, INC.
PERRY, FL—2012-08-21 00:00:00
BIG TOP TRAMPOLINE, INC.
View BIG TOP TRAMPOLINE, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332311)
BERRYVILLE, VA—2026-06-26 00:00:00
J PEREZ METAL INC
ELEANOR, WV—2026-06-23 00:00:00
PARKLINE INC.
MODESTO, CA—2026-06-18 00:00:00
KINGSPAN INSULATED PANELS, INC.
EASTON, PA—2026-06-16 00:00:00
NVS MOVING & STORAGE LLC
LAKELAND, FL—2026-06-16 00:00:00
MID-STATE MACHINE AND FABRICATING CORP.
More inspections in FL
DELAND, FL—2026-07-16 00:00:00
BALL FABRICS
GAINESVILLE, FL—2026-07-16 00:00:00
WACKY SAUCES LLC
FORT WALTON BEACH, FL—2026-07-16 00:00:00
WASTE MANAGEMENT, INC. OF FLORIDA
PONCE INLET, FL—2026-07-16 00:00:00
RESOLUTE ROOFING LLC
PALM COAST, FL—2026-07-16 00:00:00
J & J TREE EXPERTS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335316584.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.