Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: BIBLE ELECTRIC INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of BIBLE ELECTRIC INC. in 210 N. MAIN, HOLLY, CO 81047 (NAICS 238210). OSHA activity number 335332409.

Watch Bible Electric INC. — free Get an email when a new federal OSHA severe-injury report for Bible Electric INC. is published. One employer, no account, unsubscribe in one click.
Establishment
BIBLE ELECTRIC INC.
Site address
210 N. MAIN
City
HOLLY
State
CO
ZIP
81047
Mailing
3740 INTERPARK DR., HOLLY, CO 81047
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.405 A02 II I

Other-than-serious 2 exposed
Issued
Abate by
Penalty
Initial $6300.00 · Current $5000.00 Reduced
29 CFR 1926.405(a)(2)(ii)(I):  Flexible cords and cables used for temporary wiring were not protected from damage:    a)  On or about June 20, 2012 and at times prior Bible Electric Inc. did not ensure that employees were protected from electrical hazards.  Extension cords used at the WPA Gym were not protected from damage.  The temporary panel box was located so that the cords had to run across the access area where vehicles drove across them.
Recent events (2)
  • — I (O) $5000
  • — Z (S) $6300

1926.502 B13

Other-than-serious 2 exposed
Issued
Abate by
Penalty
Initial $3600.00 · Current $2000.00 Reduced
29 CFR 1926.502(b)(13):  When guardrail systems were used around holes which were used as access (such as ladderways), they were not provided with a gate, or were not so offset that a person could not walk directly into the hole:    a)  On or about June 20, 2012 and at times prior Bible Electric Inc., did not ensure that workers were protected from fall hazards.  The scaffold stairway used to access the ceiling area did not have guardrails installed to protect the stairway opening.
Recent events (2)
  • — I (O) $2000
  • — Z (S) $3600

1926.1051 A

Other-than-serious 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1051(a):  Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided:    a)  On or about June 20, 2012 and at times prior, Bible Electric Inc, did not ensure that employees were protected from fall hazards.  The distance from the top of the scaffold stairway to the work platform was over 19 inches.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

View BIBLE ELECTRIC INC.'s full OSHA safety record →