SYRACUSE, NY —
OSHA Inspection: SOLVAY IRON WORKS
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of SOLVAY IRON WORKS in 306 HIAWATHA BOULEVARD WEST, SYRACUSE, NY 13204 (NAICS 238120). OSHA activity number 335374385.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOLVAY IRON WORKS
- Site address
- 306 HIAWATHA BOULEVARD WEST
- City
- SYRACUSE
- State
- NY
- ZIP
- 13204
- Mailing
- 3546 WALTERS ROAD, SYRACUSE, NY 13209
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 30
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.1200 H03 II
- Issued
- Oct 19, 2012
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1910.1200(h)(3)(ii): Employee training did not include the physical and health hazards of the chemicals in the work area: a) Destiny USA, on or about 7/18/12: Employees welding indoors were not provided with training on the health hazards of chemicals in the work area including, but not limited to, carbon monoxide.
Recent events (3)
- — J (S) $1470
- — C (S) $2100
- — Z (S) $2100
1926.21 B05
- Issued
- Oct 19, 2012
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1926.21(b)(5): Employees required to handle or use flammable liquids, gases, or toxic materials were not instructed in the safe handling and use of those materials and were not made aware of the specific requirements contained in Subparts D, F, and other applicable subparts of this part: a) Destiny USA, on or about 8/18/12: Welders performing hot work were not trained to inspect fire extinguishers as set forth in Subpart F of the construction standard, 29 CFR 1926. Fire equipment was not inspected for use in emergencies involving liquified propane gas (LPG) in that: 1) A fire extinguisher, name and model unknown without markings was last inspected in February of 2008. 2) A Sentry ABC fire extinguisher was not inspected since July of 2005. No serial numbers or markings were discernible. The extinguisher had been discharged. 3) An Amerex model B456, 4A:80-B:C dry chemical fire extinguisher, serial E-554774 was not inspected since May/June of 2011. 4) An Amerex model B456, 4A:80-B:C dry chemical fire extinguisher, serial E-454500 was not inspected since May/June of 2011. 5) An Amerex model B456, 4A:80-B:C dry chemical fire extinguisher, serial E-453126 was not inspected since May/June of 2011. 6) An Amerex model B456, 4A:80-B:C dry chemical fire extinguisher, serial E-453135 was not inspected since May/June of 2011.
Recent events (3)
- — J (S) $1470
- — C (S) $2100
- — Z (S) $2100
1926.150 C01 VIII
- Issued
- Oct 19, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.150(c)(1)(viii): Portable fire extinguishers were not inspected periodically and maintained in accordance with maintenance and use of portable fire extinguishers, N.F.P.A. No. 10A-1970: a) Destiny USA, on or about 7/18/12: A fire extinguisher, name and model unknown without markings was last inspected in February of 2008. The extinguisher was provided for hazards resulting from welding operations. b) Destiny USA, on or about 7/18/12: A Sentry ABC fire extinguisher was not inspected since July of 2005. No serial numbers or markings were discernible. The extinguisher was provided for hazards resulting from welding operations. c) Destiny USA, on or about 7/18/12: An Amerex model B456, 4A:80-B:C dry chemical fire extinguisher, serial E-554774 was not inspected since May/June of 2011. The extinguisher was provided for hazards resulting from welding operations. d) Destiny USA, on or about 7/18/12: An Amerex model B456, 4A:80-B:C dry chemical fire extinguisher, serial E-454500 was not inspected since May/June of 2011. The extinguisher was provided for hazards resulting from welding operations. e) Destiny USA, on or about 7/18/12: An Amerex model B456, 4A:80-B:C dry chemical fire extinguisher, serial E-453126 was not inspected since May/June of 2011. The extinguisher was provided for hazards resulting from welding operations. f) Destiny USA, on or about 7/18/12: An Amerex model B456, 4A:80-B:C dry chemical fire extinguisher, serial E-453135 was not inspected since May/June of 2011. The extinguisher was provided for hazards resulting from welding operations.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.352 D
- Issued
- Oct 19, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.352(d): Suitable fire extinguishing equipment was not immediately available in the work area(s) where welding, cutting, or heating was being performed: a) Destiny USA, on or about 7/18/12: A Sentry ABC fire extinguisher was not inspected since July of 2005. No serial numbers or markings were discernible. Fire extinguisher was discharged.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at Solvay Iron Works
View Solvay Iron Works's full OSHA safety record →
More inspections in this industry (NAICS 238120)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335374385.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.