VIDOR, TX —
OSHA Inspection: SOUTHEAST TEXAS INDUSTRIES, INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of SOUTHEAST TEXAS INDUSTRIES, INC. in 635 OLD HWY 90 WEST, VIDOR, TX 77662 (NAICS 333132). OSHA activity number 335480190.
Where did this inspection happen?
- Establishment
- SOUTHEAST TEXAS INDUSTRIES, INC.
- Site address
- 635 OLD HWY 90 WEST
- City
- VIDOR
- State
- TX
- ZIP
- 77662
- Mailing
- 635 OLD HWY 90 WEST, VIDOR, TX 77662
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333132
- Employees
- 220
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.304 B03 II A
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $4200.00 Reduced
General-duty citation text
29 CFR 1910.304(b)(3)(ii)(A): All 125-volt, single-phase, 15, 20 and 30-ampere receptacle outlets that are not part of the permanent wiring of the building or structure and that are in use by personnel did not have ground-fault circuit-interrupter protection for personnel: (a) At 635 Old Hwy. 90 West, Vidor, TX, Crown Section of the fabrication shop, employees were exposed to electric shock when using a E54864 12 AWG extension cord to energize a 120 volt grinder and fan plugged into a Miller welding machine without a ground fault circuit interrupter (GFCI) for employee protection.
Recent events (2)
- — I (O) $4200
- — Z (S) $7000
1910.305 A02 X
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $4200.00 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage: (a) At 635 Old Hwy. 90 West, Vidor, TX, Crown Section of the fabrication shop, employees were exposed to electric shock when using a E54864 12 AWG extension cord to energize a 120 volt grinder and fan. The flexible cord was exposed to hot electrical equipment (welding ground), hot slag, hot metal surfaces (from welding and cutting), pinching from heavy objects, etc.
Recent events (2)
- — I (O) $4200
- — Z (S) $7000
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $4200.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) At 635 Old Hwy. 90 West, Vidor, TX, Crown Section of the fabrication shop, employees were exposed to electric shock when using a E54864 12 AWG extension cord to energize a 120 volt grinder and fan with no strain relief. (b) At 635 Old Hwy. 90 West, Vidor, TX, Crown Section of the fabrication shop, employees were exposed to electrical shock when using a ground cable connected to a ground clamp without a strain relief to conduct MIG welding.
Recent events (2)
- — I (O) $4200
- — Z (S) $7000
1910.334 A02 I
- Issued
- Abate by
- Penalty
- Initial $3000.00 · Current $1800.00 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): a) At 635 Old Hwy. 90 West, Vidor, TX, Crown Section of the fabrication shop, employees were exposed to electrical shock when using an extension cord with no strain relief, and outer jacket insulation damage.
Recent events (2)
- — I (S) $1800
- — Z (S) $3000
More inspections at SOUTHEAST TEXAS INDUSTRIES, INC.
MCALLEN, TX—2024-06-12 00:00:00
SOUTHEAST TEXAS INDUSTRIES, INC.
PUEBLO, CO—2023-10-20 00:00:00
SOUTHEAST TEXAS INDUSTRIES, INC.
VIDOR, TX—2016-02-11 00:00:00
SOUTHEAST TEXAS INDUSTRIES, INC.
View SOUTHEAST TEXAS INDUSTRIES, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333132)
BAKERSFIELD, CA—2026-06-04
S.A. CAMP PUMP & DRILLING COMPANY
WHITE HOUSE, TN—2026-05-12
PMC GAGE, INC.
LONGVIEW, TX—2026-05-11
KING TOOL COMPANY
SLIDELL, LA—2026-04-30
SPARROWS OFFSHORE, LLC
HOUSTON, TX—2026-04-02
LINDSAYCA, INC.
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335480190.