COLFAX, WI —
OSHA Inspection: BIG TIMBER SAWMILL, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of BIG TIMBER SAWMILL, LLC in 314 W. 3RD AVENUE P.O. BOX 388, COLFAX, WI 54730 (NAICS 321113). OSHA activity number 335626388.
Where did this inspection happen?
- Establishment
- BIG TIMBER SAWMILL, LLC
- Site address
- 314 W. 3RD AVENUE P.O. BOX 388
- City
- COLFAX
- State
- WI
- ZIP
- 54730
- Mailing
- 314 W. 3RD AVENUE P.O. BOX 388, COLFAX, WI 54730
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321113
- Employees
- 12
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $1700.00 · Current $1190.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) Throughout the sawmill; Energy control procedures were not evaluated within the last year.
Recent events (2)
- — I (S) $1190
- — Z (S) $1700
1910.147 C07 I A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: (a) Lower sawmill; An employee cleaning equipment that was locked out/tagged out (LOTO) did not receive authorized personnel training for LOTO.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Lower sawmill; Each authorized employee did not affix their own lock to energy isolating devices during cleaning operations.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 B
- Issued
- Abate by
- Penalty
- Initial $2040.00 · Current $1428.00 Reduced
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: (a) Lower sawmill; The long block conveyor was not secured and/or anchored. The conveyor had walked approximately 1-1/2 feet.
Recent events (2)
- — I (S) $1428
- — Z (S) $2040
1910.265 C18 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.265(c)(18)(i): Construction, operation, and maintenance of conveyors was not in accordance with American National Standard B20.1-1957, Section 804(b): Any parts showing signs of wear were not watched carefully and replaced as soon as there was any indication of excessive wear: (a) Lower sawmill, block/stick conveyor; A 30-inch wide conveyor belt was damaged, which caught the clothing of an employee. (b) Lower sawmill, long block conveyor; Damage on a 16 inch wide conveyor belt was not repaired. The missing section of conveyor belt was approximately 7 inches wide by 6-1/2 inches long.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 I
- Issued
- Abate by
- Penalty
- Initial $1020.00 · Current $714.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions: (a) Lower sawmill, beneath long block conveyor; Abrasion protection was not provided for 240-volt conductors entering a fitting for the conveyor motor.
Recent events (2)
- — I (S) $714
- — Z (S) $1020
1910.305 B01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) Lower sawmill; Knockout holes on 110-volt and 240-volt junction boxes were not closed at the flipping station and on an electric motor beneath the long block conveyor.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at BIG TIMBER SAWMILL, LLC
COLFAX, WI—2007-04-03 00:00:00
BIG TIMBER SAWMILL, LLC
COLFAX, WI—2005-07-23 00:00:00
BIG TIMBER SAWMILL, LLC
View BIG TIMBER SAWMILL, LLC's full OSHA safety record →
More inspections in this industry (NAICS 321113)
COCHRANTON, PA—2026-07-15 00:00:00
CRAWFORD COUNTY HARDWOODS, LLC
COCHRANTON, PA—2026-07-15 00:00:00
CRAWFORD COUNTY HARDWOODS, LLC
LIVE OAK, FL—2026-07-09 00:00:00
BINDERHOLZ LIVE OAK LLC
LAFAYETTE, TN—2026-07-08 00:00:00
CLARK LUMBER COMPANY, LLC
GASTON, OR—2026-07-07 00:00:00
317744699 - STIMSON LUMBER COMPANY
More inspections in WI
GREEN BAY, WI—2026-07-17 00:00:00
PTS CONTRACTORS, INC.
WAUSAU, WI—2026-07-16 00:00:00
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15 00:00:00
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15 00:00:00
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15 00:00:00
TERONOMY BUILDERS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335626388.