HOUSTON, TX —
OSHA Inspection: SISTO SALES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SISTO SALES in REMINGTON SPRINGS DRIVE, HOUSTON, TX 77073 (NAICS 238160). OSHA activity number 336175989.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SISTO SALES
- Site address
- REMINGTON SPRINGS DRIVE
- City
- HOUSTON
- State
- TX
- ZIP
- 77073
- Mailing
- 529 40 1/2 STREET, HOUSTON, TX 77073
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
1 citation on file for this inspection.
1926.501 B13
- Issued
- Sep 20, 2012
- Abate by
- Sep 21, 2012
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b): The employer does not provide fall protection during roof decking work. This violation was observed on or about September 7, 2012, on the newly construction of a residential home where employees were exposed to a fall hazard when installing roof decks 18 feet above the ground without fall protection. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that employees engaged in residential construction activities 6 feet or more above the lower levels are protected by guardrail systems, safety net system, or personal fall arrest system, or are employees provided with an alternative fall protection measure under another provision of paragraph (b).
Recent events (1)
- — Z (S) $2000
More inspections in this industry (NAICS 238160)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336175989.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.