2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: HOLTON BROTHERS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HOLTON BROTHERS, INC. in 2600 HAMPDEN COURT, CHICAGO, IL 60614 (NAICS 238990). OSHA activity number 337639819.

Watch Holton Brothers, INC. — free Get an email when a new federal OSHA severe-injury report for Holton Brothers, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2600 HAMPDEN COURT
City
CHICAGO
State
IL
ZIP
60614
Mailing
717 N. JACKSON STREET, GRAFTON, WI 53024
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
116
Ownership type
A

5 citations on file for this inspection.

1926.451 D10

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $4500.00
29 CFR 1926.451(d)(10)(i):      Ropes were not inspected for defects by a competent person prior to each work shift and after every occurrence which could have affected the ropes integrity as specified in 29 CFR 1926.451(d)(10)(i) through (d)(10)(vi):    a)  The employer did not have a competent person inspect the wire ropes prior to the employee use.     **In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).**
Recent events (2)
  • — I (O) $4500
  • — Z (S) $4500

1926.451 D12 I

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(d)(12)(i):      Wire ropes clips, when used on a suspension scaffold were not installed a mininum of 6 rope diameters apart:     a)  Wire rope clamps were not installed at least 6 rope diameters apart on the scaffold's suspension cable attached to the outrigger beam.    **In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).**
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 F03

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(f)(3):      Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:     a)  Employer did not ensure that the suspension scaffolding system and its components were inspected by a competent person before each work shift and after any occurrence that could affect the scaffold's integrity.     **In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).**
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.451 G03 IV

Deleted Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $4050.00 · Current $0.00 Reduced
29 CFR 1926.451(g)(3)(iv):      Vertical lifelines, independent support lines, and suspension ropes shall not be attached to each other, nor shall they be attached to or use the same point of anchorage, nor shall they be attached to the same point on the scaffold or personal fall arrest system:     a)  Employer allowed its employee to erect and use a vertical lifeline that was anchored to a single anchorage point.      b)  Employer allowed its employee to erect and use a single vertical lifeline to support two personal fall arrest systems.     **In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).**
Recent events (2)
  • — I (S) $0
  • — Z (S) $4050

1926.501 B01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5670.00 · Current $0.00 Reduced
29 CFR 1926.501(b)(1):      Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:     a)  An employee was not provided with fall protection and was exposed to the hazard of falling while working and traveling at the roof edge of the building.  The employee was exposed to a fall of approximately 70 feet to the concrete ground.      **In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.**
Recent events (2)
  • — I (S) $0
  • — Z (S) $5670

View HOLTON BROTHERS, INC.'s full OSHA safety record →