JACKSONVILLE, FL —
OSHA Inspection: PROFESSIONAL SUNSHINE ROOFING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PROFESSIONAL SUNSHINE ROOFING, INC. in 13507 MONTECITO PLACE, JACKSONVILLE, FL 32224 (NAICS 238160). OSHA activity number 337995211.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PROFESSIONAL SUNSHINE ROOFING, INC.
- Site address
- 13507 MONTECITO PLACE
- City
- JACKSONVILLE
- State
- FL
- ZIP
- 32224
- Mailing
- 946 SHADICK DR, ORANGE CITY, FL 32763
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Jan 8, 2013
- Penalty
- Initial $4,900 · Current $2,400 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about December 20, 2012, on a 6:12 pitch roof, employees installing water proofing material were not protected from a 20 feet fall hazard by the use of conventional fall protection system or alternative fall protection measures.
Recent events (2)
- — I (S) $2400
- — Z (S) $4900
1926.1053 B01
- Issued
- Jan 8, 2013
- Penalty
- Initial $1,785 · Current $940 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a. On or about December 20, 2012, a section of a Werner 24-feet fiberglass extension ladder only extended 1? feet above the landing surface, exposing employees to a 9 feet fall hazard.
Recent events (2)
- — I (S) $940
- — Z (S) $1785
1926.1053 B04
- Issued
- Jan 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed: a. On or about December 20, 2012, at the southwest side of the building, single sections of a Werner 24-feet fiberglass extension ladder that were not designed to be used as single ladders were used to access the roof, exposing employees to a 9-feet fall hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Professional Sunshine Roofing, INC.
View Professional Sunshine Roofing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337995211.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.