DECATUR, GA —
OSHA Inspection: WILSON WELDING SERVICE, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WILSON WELDING SERVICE, INC. in 2939 SNAPFINGER RD., DECATUR, GA 30034 (NAICS 238990). OSHA activity number 338394448.
Where did this inspection happen?
- Establishment
- WILSON WELDING SERVICE, INC.
- Site address
- 2939 SNAPFINGER RD.
- City
- DECATUR
- State
- GA
- ZIP
- 30034
- Mailing
- 2939 SNAPFINGER RD., DECATUR, GA 30034
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 23
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $3080.00 · Current $3080.00
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section On or about 01/22/2013 at 2939 Snap Finger Road Decatur, GA; specific energy control procedure were not developed where employees performed maintenance on machinery that included but was not limited to: shears, ironworker, and pressbreak which have multiple energy sources that include hydraulic, mechanical, and electrical.
Recent events (3)
- — W (S) $3080
- — C (S) $3080
- — Z (S) $3080
1910.147 C07 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: On or about 01/22/2013 at 2939 Snap Finger Road Decatur, GA; the employer did not provide lock-out tag-out training to employees the were required to perform maintenance on machinery that included but was not limited to: shears, ironworker, and pressbreak which had multiple energy sources, the employer did not provide lockout/ tagout training.
Recent events (3)
- — W (S) $0
- — C (S) $0
- — Z (S) $0
1910.147 C05 II
- Issued
- Abate by
- Penalty
- Initial $2200.00 · Current $2200.00
General-duty citation text
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices were not singularly identified: On or about 01/22/2013 at 2939 Snap Finger Road Decatur, GA; the employer had four locks that were used for lockout/ tagout purposes and one key was used to open all four locks instead of four separate keys instead of being keyed differently.
Recent events (3)
- — W (S) $2200
- — C (S) $2200
- — Z (S) $2200
1910.157 E02
- Issued
- Penalty
- Initial $1122.00 · Current $1122.00
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: On or about 01/22/2013 at 2939 Snap Finger Road Decatur, Ga; an overcharged fire extinguisherhad not been inspected since 11/21/2012.
Recent events (3)
- — W (S) $1122
- — C (S) $1122
- — Z (S) $1122
1910.157 E03
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: On or about 01/22/2013 at 2939 Snap Finger Road Decatur, Ga; where employees are required to fight incipient level fires the employer had not performed an annual inspection of the portable fire extinguishers since 07/25/2011.
Recent events (3)
- — W (S) $0
- — C (S) $0
- — Z (S) $0
1910.253 B02 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: On or about 01/22/2013 at 2939 Snap Finger Road Decatur, Ga; compressed gas cylinders located in the shop were not capped.
Recent events (3)
- — W (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at WILSON WELDING SERVICE, INC.
DECATUR, GA—2024-11-27
WILSON WELDING SERVICE, INC.
DECATUR, GA—2013-01-23 00:00:00
WILSON WELDING SERVICE, INC.
View WILSON WELDING SERVICE, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238990)
NEW YORK, NY—2026-07-09
PALM INDUSTRIES LLC
NEW YORK, NY—2026-07-09
PALM INDUSTRIES LLC
EL PASO, TX—2026-07-09
RM CRANE & RIGGING LLC.
LAKEWOOD, WA—2026-07-08
WA317992018 - HARMON INC DBA HARMON SERVICE GLAZING INC
VICTOR, NY—2026-07-08
DIMARCO CONSTRUCTORS
More inspections in GA
ROME, GA—2026-07-13
CAMP INDUSTRIES
SOUTH FULTON, GA—2026-07-10
REEDWICK, LLC
CONYERS, GA—2026-07-10
GOLDEN STATE FOODS
DALTON, GA—2026-07-10
ENGINEERED FLOORS, LLC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338394448.